Removal Procedure
- Remove the I/P carrier. Refer to
Instrument Panel Carrier Replacement .
- Disconnect the electrical connector (4) from
the right air temperature actuator (3).
- Remove the screws from the right air temperature actuator (3).
- Remove the right air temperature actuator (3) from the HVAC module
assembly (2).
Installation Procedure
- Install the right air temperature actuator (3)
from the HVAC module assembly (2).
Notice: Refer to Fastener Notice in the Preface section.
- Install the screws to the right air temperature actuator (3).
Tighten
Tighten the screws to 2 N·m (18 lb in).
- Connect the electrical connector to the right air temperature actuator.
- Install the I/P carrier. Refer to
Instrument Panel Carrier Replacement .
- Reprogram the air temperature actuator. Refer to
Actuator Recalibration
.