The following DTCs are for the starter/generator control module (SGCM) coolant pump relay:
• | P0A06 is for the SGCM coolant pump relay control circuit low voltage condition. |
• | P0A07 is for the SGCM coolant pump relay control circuit high voltage condition. |
The SGCM controls the coolant pump operation by applying voltage to the coolant pump relay control circuit with an internal solid state device called a driver. When the SGCM is commanding the relay ON, the voltage of the control circuit should be low, near 0 volts. When the SGCM is commanding the relay OFF, the voltage potential of the control circuit should be high, near 12 volts.
The SGCM monitors the relay control circuit for the following conditions:
• | Short to ground |
• | Short to voltage |
• | An open circuit |
If the SGCM detects an improper voltage level on the coolant pump control circuit, then DTC P0A06 or P0A07 will set and the driver will be disabled.
This diagnostic procedure supports the following DTCs:
• | DTC P0A06 Battery Energy Control Module Read Only Memory (ROM) |
• | DTC P0A07 Battery Energy Control Module 5-Volt Reference Circuit |
• | The engine has been running for 30 seconds. |
• | The SGCM has received voltage on the ignition 0 voltage circuit. |
• | The SGCM has turned ON and no configuration DTC are present. |
• | For DTC P0A06 the SGCM coolant pump is commanded OFF. |
• | For DTC P0A07 the SGCM coolant pump is commanded ON. |
• | For DTC P0A06 the SGCM detects a low voltage condition on the SGCM coolant pump relay control circuit. |
• | For DTC P0A07 the SGCM detects a high voltage condition on the SGCM coolant pump relay control circuit. |
• | The control module illuminates the malfunction indicator lamp (MIL) on the second consecutive ignition cycle that the diagnostic runs and fails. |
• | The control module records the operating conditions at the time the diagnostic fails. The first time the diagnostic fails, the control module stores this information in the Failure Records. If the diagnostic reports a failure on the second consecutive ignition cycle, the control module records the operating conditions at the time of the failure. The control module writes the operating conditions to the Freeze Frame and updates the Failure Records. |
• | The control module turns OFF the malfunction indicator lamp (MIL) after 3 consecutive ignition cycles that the diagnostic runs and does not fail. |
• | A current DTC, Last Test Failed, clears when the diagnostic runs and passes. |
• | A history DTC clears after 40 consecutive warm-up cycles, if no failures are reported by this or any other emission related diagnostic. |
• | Clear the MIL and the DTC with a scan tool. |
If condition is not present, refer to Testing for Intermittent Conditions and Poor Connections .
The numbers below refer to the step numbers on the diagnostic table.
During the SGCM coolant pump relay operation, listen for an audible click. Command the ON and the OFF states. Repeat the commands as necessary.
This step verifies that the SGCM is providing voltage to the SGCM coolant pump relay.
This step tests for an open in the ground circuit to the SGCM coolant pump relay.
This step tests for constant voltage to the SGCM coolant pump relay.
Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: Hybrid Cooling Schematics Connector End View Reference: Hybrid Cooling Connector End Views | |||
1 | Did you perform the Diagnostic System Check - Vehicle? | Go to Step 2 | |
Does the SGCM coolant pump relay turn ON and OFF with each command? | Go to Diagnostic Aids | Go to Step 3 | |
Probe the control circuit of the SGCM coolant pump relay with a test lamp that is connected to battery positive voltage. Does the test lamp turn ON and OFF with each command? | Go to Step 4 | Go to Step 5 | |
Does the test lamp turn ON and OFF with each command? | Go to Step 8 | Go to Step 10 | |
Does the test lamp remain illuminated with each command? | Go to Step 7 | Go to Step 6 | |
6 | Test the control circuit of the SGCM coolant pump relay for a short to ground and an open. Refer to Circuit Testing and to Wiring Repairs . Did you find and correct the condition? | Go to Step 13 | Go to Step 9 |
7 | Test the control circuit of the SGCM coolant pump relay for a short to voltage. Refer to Circuit Testing and to Wiring Repairs . Did you find and correct the condition? | Go to Step 13 | Go to Step 9 |
8 | Inspect for poor connections at the SGCM coolant pump relay. Refer to Testing for Intermittent Conditions and Poor Connections and to Connector Repairs . Did you find and correct the condition? | Go to Step 13 | Go to Step 11 |
9 | Inspect for poor connections at the harness connector of the SGCM. Refer to Testing for Intermittent Conditions and Poor Connections and to Connector Repairs . Did you find and correct the condition? | Go to Step 13 | Go to Step 12 |
10 | Repair the ground circuit of the SGCM coolant pump relay. Refer to Wiring Repairs . Did you complete the repair? | Go to Step 13 | -- |
11 |
Important: Perform the programming procedure for the SGCM. Replace the SGCM coolant pump relay. Refer to Relay Replacement . Did you complete the replacement? | Go to Step 13 | -- |
12 | Replace the SGCM. Refer to Control Module References for replacement, setup, and programming. Did you complete the replacement? | Go to Step 13 | -- |
13 |
Does the DTC reset? | Go to Step 2 | System OK |