Evaporator Tube Replacement Non-HP2
Special Tools
J 39400-A Halogen Leak Detector
Removal Procedure
- Recover the refrigerant. Refer to
Refrigerant Recovery and Recharging.
- Remove the upper radiator air baffle and deflector. Refer to
Radiator Air Upper Baffle and Deflector Replacement.
- Remove the air cleaner assembly. Refer to
Air Cleaner Assembly Replacement.
- Remove the surge tank hold down nut and bolt and position aside.
Note: Do not open cooling system.
- Remove the evaporator tube nut from the evaporator.
- Disconnect the evaporator tube from the evaporator.
- Remove the evaporator tube nut from the auxiliary A/C tube, if equipped.
- Disconnect the evaporator tube from the auxiliary A/C tube, if equipped.
- Remove the evaporator tube nut from the condenser.
- Disconnect the evaporator tube from the condenser.
- Remove the evaporator tube from the vehicle.
- Discard all of the used sealing washers. Cap all of the open connections.
Installation Procedure
- Connect the evaporator tube to the condenser using new sealing washers. Refer to
Sealing Washer Replacement.
Caution: Refer to Fastener Caution in the Preface section.
- Install the evaporator tube nut to the condenser and tighten to
16 N·m (12 lb ft).
- Connect the evaporator tube to the auxiliary A/C tube using new sealing washers, if equipped. Refer to
Sealing Washer Replacement.
- Install the evaporator tube nut to the auxiliary A/C tube, if equipped, and tighten to
16 N·m (12 lb ft).
- Install the evaporator tube to the evaporator.
- Install the evaporator tube nut to the evaporator and tighten to
16 N·m (12 lb ft).
- Install the surge tank hold down nut and bolt and position aside.
- Install the air cleaner assembly. Refer to
Air Cleaner Assembly Replacement.
- Install the upper radiator air baffle and deflector. Refer to
Radiator Air Upper Baffle and Deflector Replacement.
- Evacuate and recharge the system. Refer to
Refrigerant Recovery and Recharging.
- Leak test the fittings of the components using the
J 39400-A .