Special Tools
J 43181 Heater Line QC Release Tool
Removal Procedure
- Drain the engine coolant. Refer to
Cooling System Draining and Filling.
- Using the
J 43181 disconnect the inlet heater hose from the heater core.
2.1. | Install the
J 43181 to the heater core pipe. |
2.2. | Close the tool around the heater core pipe. |
2.3. | Firmly pull the tool into the quick connect end of the heater hose. |
2.4. | Firmly grasp the heater hose. Pull the heater hose forward in order to disengage the inlet hose from the heater core. |
- Using the
J 43181 disconnect the surge tank outlet hose from the heater core.
3.1. | Install the
J 43181 to the heater core pipe. |
3.2. | Close the tool around the heater core pipe. |
3.3. | Firmly pull the tool into the quick connect end of the heater hose. |
3.4. | Firmly grasp the heater hose. Pull the heater hose forward in order to disengage the surge tank outlet hose from the heater core. |
- Remove the upper intake manifold sight shield. Refer to
Upper Intake Manifold Sight Shield Replacement.
- Remove the battery. Refer to
Battery Replacement.
- Remove the accumulator. Refer to
Air Conditioning Accumulator Replacement.
- Remove the instrument panel to the service position. Refer to
Instrument Panel Service Positioning.
- Remove the nuts (2) from the HVAC module (3).
- Remove the bolts (1) from the HVAC module (3).
- Remove the HVAC module (3).
Installation Procedure
- If replacing the HVAC module, transfer the components from the old HVAC module as necessary.
- Install the HVAC module (3).
Caution: Refer to Fastener Caution in the Preface section.
- Install the nuts (2) to the HVAC module (3).
Tighten
Tighten the nuts to 9 N·m (80 lb in).
- Install the bolts (1) to the HVAC module (3).
Tighten
Tighten the bolts to 4 N·m (35 lb in).
- Connect the electrical harness and the ground connections.
- Install the HVAC module drain hose.
- Install the instrument panel. Refer to
Instrument Panel Service Positioning.
- Install the upper intake manifold sight shield. Refer to
Upper Intake Manifold Sight Shield Replacement.
- Install the battery. Refer to
Battery Replacement.
- Install the accumulator. Refer to
Air Conditioning Accumulator Replacement.
- Install the surge tank outlet hose to the heater core.
Firmly push the quick connect onto the heater core pipe until you hear an audible click.
- Install the inlet heater hose to the heater core.
Firmly push the quick connect onto the heater core pipe until you hear an audible click.
- Fill the engine coolant. Refer to
Cooling System Draining and Filling.