Special Tools
J 43181
Heater Line QC Release Tool
Removal Procedure
- Drain the engine coolant. Refer to
Cooling System Draining and Filling
.
- Using the
J 43181
disconnect the inlet heater hose from the heater core.
2.1. | Install the
J 43181
to the heater core pipe. |
2.2. | Close the tool around the heater core pipe. |
2.3. | Firmly pull the tool into the quick connect end of the heater hose. |
2.4. | Firmly grasp the heater hose. Pull the heater hose forward in order to disengage the inlet hose from the heater core. |
- Using the
J 43181
disconnect the surge tank outlet hose from the heater core.
3.1. | Install the
J 43181
to the heater core pipe. |
3.2. | Close the tool around the heater core pipe. |
3.3. | Firmly pull the tool into the quick connect end of the heater hose. |
3.4. | Firmly grasp the heater hose. Pull the heater hose forward in order to disengage the surge tank outlet hose from the heater core. |
- Remove the upper intake manifold sight shield. Refer to
Upper Intake Manifold Sight Shield Replacement
.
- Remove the battery. Refer to
Battery Replacement
.
- Remove the accumulator. Refer to
Air Conditioning Accumulator Replacement
.
- Remove the instrument panel to the service position. Refer to
Instrument Panel Service Positioning
.
- Remove the nuts (2) from the HVAC module (3).
- Remove the bolts (1) from the HVAC module (3).
- Remove the HVAC module (3).
Installation Procedure
- If replacing the HVAC module, transfer the components from the old HVAC module as necessary.
- Install the HVAC module (3).
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the nuts (2) to the HVAC module (3).
Tighten
Tighten the nuts to 9 N·m (80 lb in).
- Install the bolts (1) to the HVAC module (3).
Tighten
Tighten the bolts to 4 N·m (35 lb in).
- Connect the electrical harness and the ground connections.
- Install the HVAC module drain hose.
- Install the instrument panel. Refer to
Instrument Panel Service Positioning
.
- Install the upper intake manifold sight shield. Refer to
Upper Intake Manifold Sight Shield Replacement
.
- Install the battery. Refer to
Battery Replacement
.
- Install the accumulator. Refer to
Air Conditioning Accumulator Replacement
.
- Install the surge tank outlet hose to the heater core.
Firmly push the quick connect onto the heater core pipe until you hear an audible click.
- Install the inlet heater hose to the heater core.
Firmly push the quick connect onto the heater core pipe until you hear an audible click.
- Fill the engine coolant. Refer to
Cooling System Draining and Filling
.