Air Conditioning Compressor Replacement HP2
Callout
| Component Name
|
Danger: Always perform the High Voltage Disabling procedure prior to servicing any High
Voltage component or connection. Personal Protection Equipment (PPE) and proper procedures must be followed.
The High Voltage Disabling procedure will perform the following tasks:
• | Identify how to disable high voltage. |
• | Identify how to test for the presence of high voltage. |
• | Identify condition under which high voltage is always present and personal protection equipment (PPE) and proper procedures must be followed. |
Failure to follow the procedures exactly as written may result in serious injury or death.
Preliminary Procedures
- Disable hybrid high voltage system. Refer to
High Voltage Disabling and
High Voltage Enabling.
- Recover the refrigerant. Refer to
Refrigerant Recovery and Recharging.
- Remove the air cleaner. Refer to
Air Cleaner Assembly Replacement.
- Remove the air cleaner resonator outlet duct. Refer to
Air Cleaner Resonator Outlet Duct Replacement.
- Remove the suction hose. Refer to
Suction Hose Replacement
- Remove the discharge hose. Refer to
Discharge Hose Replacement
- Raise and support the vehicle. Refer to
Lifting and Jacking the Vehicle.
- Remove the engine shield. Refer to
Engine Shield Replacement.
- Remove the oil pan skid plate. Refer to
Oil Pan Skid Plate Replacement.
|
1
| A/C Compressor Cable Bolt (Qty: 2)
Caution: High Voltage (HV) cables should never be removed from the mounting block. Removal of the individual HV cable from the mounting block may result in HV cable and/or component damage from improper:
• | Terminal position assurance |
Caution: Refer to Fastener Caution in the Preface section.
Tighten 9 N·m (80 lb in) |
2
| A/C Compressor Cable Mounting Bolt (Qty: 2)
Tighten 9 N·m (80 lb in) |
3
| A/C Compressor Cable
|
4
| A/C Compressor Seal
ProcedureRemove and discard the seal.
|
5
| A/C Compressor Bolt (Qty: 3)
Tighten 50 N·m (37 lb ft) |
6
| A/C Compressor
Procedure
- Disconnect three wire low voltage electrical connector from compressor.
- Insert bottom compressor bolts into compressor before installing compressor to vehicle.
- Reprogram A/C compressor. Refer to
Air Conditioning Compressor Control Module Programming and Setup
|
Air Conditioning Compressor Replacement LY2, LY5, LH6, L76, L92 and LMG
Special Tools
J 39400-A Halogen Leak Detector
Removal Procedure
- Recover the refrigerant. Refer to
Refrigerant Recovery and Recharging.
- Install a ratchet into the air conditioning (A/C) belt tensioner adapter opening.
- Remove the air cleaner resonator outlet duct. Refer to
Air Cleaner Resonator Outlet Duct Replacement.
- Rotate the A/C belt tensioner clockwise in order to relieve the tension on the belt.
- Remove the A/C belt from the A/C compressor.
- Slowly release the tension on the A/C belt tensioner.
- Remove the discharge hose bolt from the A/C compressor.
- Remove the discharge hose from the A/C compressor.
- Remove the suction hose bolt from the A/C compressor.
- Remove the suction hose from the A/C compressor.
- Discard the sealing washers. Cap all of the openings.
- Disconnect the electrical connections.
- Remove the A/C compressor mounting bolts. The lower right bolt (3) will stay with the compressor due to a lack of clearance.
- Remove the A/C compressor (2) from the bracket (1).
- If replacing the A/C compressor. Refer to
Air Conditioning Compressor Oil Balancing.
Installation Procedure
- Install the A/C compressor (2) to the bracket (1) through the fender well. Insert the mounting bolt (3) into the lower right mounting boss before installing the A/C compressor.
- Install the A/C compressor to the bracket. Insert the mounting bolt into the lower right mount before installing the A/C compressor.
Caution: Refer to Fastener Caution in the Preface section.
- Install the A/C compressor mounting bolts and tighten to
50 N·m (37 lb ft).
- Connect the electrical connector to the A/C compressor.
- Install the A/C discharge hose to the compressor using new sealing washers. Refer to
Sealing Washer Replacement.
- Install the A/C discharge hose bolt to the A/C compressor and tighten to
16 N·m (12 lb ft).
- Install the A/C suction hose to the compressor using new sealing washers. Refer to
Sealing Washer Replacement.
- Install the A/C suction hose bolt to the A/C compressor and tighten to
16 N·m (12 lb ft).
- Install the A/C drive belt. Refer to
Air Conditioning Compressor Belt Replacement.
- Evacuate and recharge the A/C system. Refer to
Refrigerant Recovery and Recharging.
- Install the air cleaner resonator outlet duct. Refer to
Air Cleaner Resonator Outlet Duct Replacement.
- Leak test the fittings of the component using the
J 39400-A .
Air Conditioning Compressor Replacement LLY/LMM
Special Tools
J 39400-A Halogen Leak Detector
Removal Procedure
- Recover the refrigerant. Refer to
Refrigerant Recovery and Recharging.
- Install a ratchet into the belt tensioner adapter opening.
- Rotate the belt tensioner counterclockwise in order to relieve the tension on the belt.
- Remove the belt from the A/C compressor.
- Slowly release the tension on the belt tensioner.
- Remove the discharge hose bolt (2) from the A/C compressor (3).
- Remove the discharge hose (1) from the A/C compressor (3).
- Remove the suction hose bolt (2) from the A/C compressor (3).
- Remove the suction hose (1) from the A/C compressor (3).
- Discard the sealing washers. Cap all of the openings.
- Disconnect the electrical connections.
- Remove the A/C compressor mounting bolts.
- If replacing the A/C compressor. Refer to
Air Conditioning Compressor Oil Balancing.
Installation Procedure
- Remove the caps or tape from the hose and line ends.
- Install the A/C compressor.
Caution: Refer to Fastener Caution in the Preface section.
- Install the A/C compressor mounting bolts.
Tighten
Tighten the bolts to 50 N·m (37 lb ft).
- Connect the electrical connection.
- Install the A/C discharge hose (1) to the compressor (3) using new sealing washers.
- Install the A/C discharge hose bolt (2) to the A/C compressor (3).
Tighten
Tighten the bolt to 16 N·m (12 lb ft).
- Install the A/C suction hose (1) to the compressor (3) using new sealing washers.
- Install the A/C suction hose bolt (2) to the A/C compressor (3).
Tighten
Tighten the bolt to 16 N·m (12 lb ft).
- Install the drive belt. Refer to
Drive Belt Replacement.
- Evacuate and recharge the A/C system. Refer to
Refrigerant Recovery and Recharging.
- Leak test the fittings of the component using the
J 39400-A .
Air Conditioning Compressor Replacement LU3
Special Tools
J 39400-A Halogen Leak Detector
Removal Procedure
- Recover the refrigerant. Refer to
Refrigerant Recovery and Recharging.
- Install a ratchet into the belt tensioner adapter opening.
- Rotate the belt tensioner counterclockwise in order to relieve the tension on the belt.
- Remove the belt from the A/C compressor.
- Slowly release the tension on the belt tensioner.
- Remove the discharge and suction hose bolt from the A/C compressor.
- Remove the discharge and suction hose from the A/C compressor.
- Discard the sealing washers. Cap all of the openings.
- Disconnect the electrical connections.
- Remove the A/C compressor mounting bolts.
- If replacing the A/C compressor. Refer to
Air Conditioning Compressor Oil Balancing.
Installation Procedure
- Remove the caps or tape from the hose and line ends.
- Install the A/C compressor.
Caution: Refer to Fastener Caution in the Preface section.
- Install the A/C compressor mounting bolts.
Tighten
Tighten the bolts to 50 N·m (37 lb ft).
- Connect the electrical connection.
- Install the A/C discharge and suction hose to the compressor using new sealing washers.
- Install the A/C discharge and suction hose bolt to the A/C compressor.
Tighten
Tighten the bolt to 16 N·m (12 lb ft).
- Install the drive belt. Refer to
Drive Belt Replacement.
- Evacuate and recharge the A/C system. Refer to
Refrigerant Recovery and Recharging.
- Leak test the fittings of the component using the
J 39400-A .