GM Service Manual Online
For 1990-2009 cars only

Circuit Description

The engine control module (ECM) supplies a voltage near 450 mV between the heated oxygen sensor (HO2S) high signal circuit and the low reference circuit. The HO2S varies the voltage over a range from about 1,000 mV when the exhaust is rich, down through about 10 mV when the exhaust is lean.

The ECM monitors and stores the HO2S voltage information. The ECM evaluates the HO2S voltage samples in order to determine the amount of time that the HO2S voltage was out of range. The ECM compares the stored HO2S voltage samples taken within each sample period and determines if the majority of the samples are out of the operating range.

The HO2S utilizes the following circuits:

    • A signal circuit
    • A low reference circuit
    • An ignition 1 voltage circuit
    • A heater control circuit

The ECM monitors the HO2S voltage for being fixed below a predetermined voltage or within the bias voltage range. If the ECM detects the voltage is too low or is within the bias voltage range, this DTC sets.

DTC Descriptor

This diagnostic procedure supports the following DTC:

DTC P0137 HO2S Circuit Low Voltage Sensor 2

Conditions for Running the DTC

Closed Loop Test

    • DTCs P0107, P0108, P0117, P0118, P0122, P0123, P0335, P0336, P0341, P0342, P0400, P0404, P0405, and P0406 are not set.
    • The engine is running.
    • The engine speed is less than 6,000 RPM.
    • The DTC runs continuously once the above conditions are met.

Decel Fuel Cut-Off (DFCO) Test

    • The H02S test is ran when the following conditions are met during DFCO mode:
       - DTCs P0107, P0108, and P0141 are not set.
       - The ignition 1 voltage is more 10 volts.
       - The engine speed is less than 6000 RPM.
       - The fuel system is in closed loop.
       - The mass air flow is more than 40 g/s during decel fuel cut-off.
    • The DTC runs continuously once the above conditions are met.

Conditions for Setting the DTC

Closed Loop Test

    • The ECM detects that the HO2S voltage is less than 70 mV.
    • The condition exists for more than 40 seconds.

Decel Fuel Cut-Off (DFCO) Test

    • The ECM detects that the HO2S voltage is between 352-499 mV.
    • The condition exists for more than 10 seconds.

Action Taken When the DTC Sets

    • The malfunction indicator lamp (MIL) will illuminate after 3 consecutive trips with a fail.
    • The ECM will record operating conditions at the time the diagnostic fail. This information will be stored in the Freeze Frame and Failure Records buffers.
    • The coolant fan turns ON.

Conditions for Clearing the MIL/DTC

    • The MIL will turn OFF after 4 consecutive ignition cycles in which the diagnostic runs without a fault.
    • DTCs can be cleared by using the scan tool.
    • Disconnect the ECM battery feed for 10 seconds.

Step

Action

Values

Yes

No

Schematic Reference: Engine Controls Schematics

Connector End View Reference: Engine Control Module Connector End Views or Engine Controls Connector End Views

1

Did you perform the Diagnostic System Check - Engine Controls?

--

Go to Step 2

Go to Diagnostic System Check - Engine Controls

2

  1. Start the engine.
  2. Allow the engine to reach the normal operating temperature.
  3. Operate the engine above 1,200 RPM for 30 seconds and then allow the engine to idle.
  4. Observe the heated oxygen sensor (HO2S) 2 voltage parameter with a scan tool.

Does the voltage fluctuate above and below the specified range?

352-499 mV

Go to Step 3

Go to Step 4

3

  1. Observe the Freeze Frame/Failure Records for this DTC.
  2. Turn OFF the ignition for 30 seconds.
  3. Start the engine.
  4. Operate the vehicle within the Conditions for Running the DTC.

Did the DTC fail this ignition?

--

Go to Step 4

Go to Intermittent Conditions

4

  1. Turn OFF the ignition.
  2. Disconnect the HO2S 2 harness connector.
  3. Turn ON the ignition, with the engine OFF.
  4. Observe the HO2S 2 voltage parameter with a scan tool.

Is the voltage within the specified range?

350-550 mV

Go to Step 5

Go to Step 7

5

  1. Connect a 3-ampere fused jumper wire between the signal circuit and the low reference circuit of the HO2S.
  2. Observe the HO2S 2 voltage parameter with a scan tool.

Is the voltage less than the specified value?

20 mV

Go to Step 9

Go to Step 6

6

  1. Connect a 3-ampere fused jumper wire between the HO2S signal circuit and a good ground.
  2. Observe the HO2S 2 voltage parameter with a scan tool.

Is the voltage less than the specified value?

20 mV

Go to Step 8

Go to Step 7

7

Test the HO2S signal circuit for one of the following conditions:

    • A short to ground
    • An open
    • High resistance

Refer to Circuit Testing and Wiring Repairs in Wiring Systems.

Did you find and correct the condition?

--

Go to Step 14

Go to Step 11

8

Test the HO2S low reference circuit for one of the following conditions:

    • An open
    • High resistance

Refer to Circuit Testing and Wiring Repairs in Wiring Systems.

Did you find and correct the condition?

 

Go to Step 14

Go to Step 11

9

Test or inspect for the following conditions:

    • Lean fuel injectors--Refer to Fuel Injector Balance Test with Special Tool .
    • Low fuel system pressure--Refer to Fuel System Diagnosis .
    • Fuel that is contaminated.
    • Exhaust leaks near the HO2S .
    • Engine vacuum leaks

Did you find and correct the condition?

--

Go to Step 14

Go to Step 10

10

Test for shorted terminals and poor connections at the HO2S. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems.

Did you find and correct the condition?

--

Go to Step 14

Go to Step 12

11

Test for shorted terminals and poor connections at the engine control module (ECM). Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems.

Did you find and correct the condition?

--

Go to Step 14

Go to Step 13

12

Replace the HO2S. Refer to Heated Oxygen Sensor 2 Replacement .

Did you complete the replacement?

--

Go to Step 14

--

13

Replace the ECM. Refer to Engine Control Module Replacement .

Did you complete the replacement?

--

Go to Step 14

--

14

  1. Clear the DTCs with a scan tool.
  2. Turn OFF the ignition for 30 seconds.
  3. Start the engine.
  4. Operate the vehicle within the Conditions for Running the DTC.

Did the DTC fail this ignition?

--

Go to Step 2

Go to Step 15

15

Are there any DTCs that have not been diagnosed?

--

Go to Diagnostic Trouble Code (DTC) List

System OK