Removal Procedure
Caution: Refer to Battery Disconnect Caution in the Preface section.
- Disconnect the negative battery cable.
- Disconnect the camshaft position (CMP) sensor connector.
- Remove the CMP sensor retaining bolt.
- Remove the CMP sensor.
Installation Procedure
Notice: Refer to Fastener Notice in the Preface section.
- Install the CMP sensor and retaining bolts.
Tighten
Tighten the CMP sensor retaining bolt to 10-14 N·m (89-124 lb in).
- Connect the CMP sensor connector.
- Connect the negative battery cable.