• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provide an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
B+ Voltage - Coil (85) | P0562, P1611 | P0341, P0562, P1611 | -- | -- |
B+ Voltage - Switch (30) | P0562, P1611 | P0562 | -- | -- |
EC Ignition Relay Control (86) | P1611 | P0562, P1611 | P0341, P0562, P1610 | -- |
Ignition 1 Supply Voltage-ECM (87) | P0562, P1611 | P0562, P1611 | -- | -- |
The engine controls (EC) ignition relay or main relay, is controlled by the engine control module (ECM) depending upon input from the ignition switch. Battery positive voltage is supplied to the relay coil and switch. When the ignition switch is turned to the ON position, the ECM will provide ground on the control circuit of the relay using a low side driver. This will allow voltage through the relay switch contacts to the components. The ECM monitors the voltage level on the control circuit of the relay.
• | The ignition is ON or the engine is operating. |
• | The DTCs run continuously once the above condition is met. |
The ECM detects a short to voltage on the control circuit of the relay.
The ECM detects an open or short to ground on the control circuit of the relay.
DTC P1610 and P1611 are Type C DTCs.
DTC P1610 and P1611 are Type C DTCs.
Engine Controls Connector End Views
Powertrain Diagnostic Trouble Code (DTC) Type Definitions
⇒ | If the test lamp does not illuminate, repair the B+ voltage circuit for a short to ground or an open/high resistance. Replace the fuse as necessary |
⇒ | If the test lamp remains ON all the time, test for a short to ground on the control circuit. If the circuit/connections test normal, replace the ECM. |
⇒ | If the test lamp remains OFF all the time, test for a short to voltage or an open/high resistance on the control circuit. If circuit/connections test normal, replace the ECM. |
⇒ | If the resistance is not within the specified range, replace the EC ignition relay. |
• | 30 and 86 |
• | 30 and 87 |
• | 30 and 85 |
• | 85 and 87 |
⇒ | If continuity is detected, replace the EC ignition relay. |
⇒ | If the resistance measures more than 2 ohms, replace the EC ignition relay. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for engine control module replacement, setup, and programming |