Removal Procedure
Caution: Refer to Battery Disconnect Caution in the Preface section.
- Disconnect the negative battery cable.
- Disconnect the blower motor electrical connector.
- Remove the screws that secure the motor to the heater/air distribution case.
- Remove the motor and the seal from the heater/air distribution case by gently pulling the motor straight down and out.
Installation Procedure
- Install the blower motor and seal, with the shock mount pads, in the heater/air distribution case. Hold the blower motor in position.
- Install the blower motor screws to secure the blower motor to the heater/air distribution case.
- Connect the electrical connector.
- Connect the negative battery cable.
- Confirm that the blower motor operates properly.