• | EN 46597 (09916-37320) Valve Guide Reamer (5 mm or 0.1969 in) |
• | EN 46570 (09916-38210) Valve Guide Reamer (11 mm or 0.4331 in) |
• | EN 46569 (09916-14510) Valve Spring Compressor |
• | EN 46573 (09917-88220) Valve Guide Installer Attachment |
Notice: Heat the cylinder head uniformly at a temperature 80-100°C (176-212°F) in order not to deform the cylinder head. Drive the new valve guide completely into the cylinder head with the valve guide installer.
Important: Once disassembled, do not reuse the valve guide. Replace it with the new oversized valve guide.
• | The valve guide oversize is 0.03 mm (0.0012 in). |
• | The valve guide protrusion is 14 mm (0.5512 in). |
Specification
The valve guide bore width is 5 mm (0.1969 in).
Notice: Tapping or hitting the tool may cause damage to the seal.
Important: Do not reuse the disassembled oil seal. Replace the disassembled oil seal with a new one.
Important: When installing the new oil seal, knee tap or hit the tool with a hammer.
Important: Before installing the valve, coat the stem seal, valve guide, and valve stem with engine oil.
Caution: Valve springs can be tightly compressed. Use care when removing the retainers and plugs. Personal injury could result.
Notice: Use extreme care when installing the camshaft not to nick, scratch, or damage the camshaft lobes or bearing surfaces.
Notice: Refer to Fastener Notice in the Preface section.
Tighten
Tighten the screws to 10 N·m (89 lb in).
Important: The rocker arm shaft for the intake valves and the exhaust valves are different and their directions of installation are different.
Tighten
Tighten the bolts to 10 N·m (89 lb in).
Important: Before tightening the intake manifold nuts, tighten the intake manifold support bracket nut.
• | Tighten the intake manifold nuts and the bolts to 17 N·m (13 lb ft). |
• | Tighten the intake manifold bracket bolt to 10 N·m (89 lb in). |
Tighten
Tighten the exhaust manifold nuts and bolts to 22 N·m (16 lb ft).
Tighten
Tighten the exhaust manifold heat shield bolts to 10 N·m (89 lb in).
Tighten
Tighten the water outlet case mounting bolts to 10.5 N·m (93 lb in).