GM Service Manual Online
For 1990-2009 cars only

Removal Procedure

  1. Remove the floor air outlet. Refer to Air Outlet Replacement, Floor.

  2. Object Number: 290838  Size: SH
  3. Disconnect the center outlet duct vacuum actuator linkage from the center outlet duct valve.
  4. Roll the instrument panel back. Refer to Instrument Panel Carrier Replacement in Instrument Panel, Gauges and Console.

  5. Object Number: 290841  Size: SH
  6. Disconnect the two vacuum hoses.
  7. Remove the center outlet duct vacuum actuator from the bracket.

Installation Procedure


    Object Number: 290841  Size: SH
  1. Install the center outlet duct vacuum actuator to the bracket.
  2. Connect the two vacuum hoses.
  3. Roll the instrument panel forward. Refer to Instrument Panel Carrier Replacement in Instrument Panel, Gauges and Console.

  4. Object Number: 290838  Size: SH
  5. Connect the center outlet duct vacuum actuator linkage to the center outlet duct valve.
  6. Install the floor air outlet.