Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 |
Does the test lamp light? | -- | Go to Step 3 | Go to Step 2 |
2 | Repair the open in CKT 343 (YEL) from the right power window master switch connector to the IP fuse block. Is the repair complete? | -- | System OK | -- |
3 | Connect a test lamp from CKT 343 (YEL) at the right power window master switch connector C1 cavity L to CKT 150 (BLK) at the right power window master switch connector cavity F. Does the test lamp light? | -- | Go to Step 5 | Go to Step 4 |
4 | Repair the open in the CKT 150 (BLK) from the right power window master switch connector C1 cavity C to ground. Is the repair complete? | -- | System OK | -- |
5 |
Is the repair complete? | -- | System OK | -- |
Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 |
Does the test lamp light? | -- | Go to Step 3 | Go to Step 2 |
2 | Repair the open in CKT 343 (YEL) from the right front power window master switch connector C1 cavity L to the IP fuse block. Is the repair complete? | -- | System OK | -- |
3 | Connect a test lamp from CKT 343 (YEL) at the right front power window master switch connector C1 cavity L to CKT 150 (BLK) at the right front power window master switch connector C2 cavity C. Does the test lamp light? | -- | Go to Step 5 | Go to Step 4 |
4 | Repair the open in the CKT 150 (BLK) from the right front power window master switch connector C2 cavity C to ground. Is the repair complete? | -- | System OK | -- |
5 |
Is the repair complete? | -- | System OK | -- |