Valve Rocker Arm Cover Replacement Left
Removal Procedure
- Disconnect the battery negative cable assembly from the battery
negative terminal. Refer to
Caution: Unless directed otherwise, the ignition and start switch must be in the OFF or LOCK position, and all electrical loads must be OFF before servicing
any electrical component. Disconnect the negative battery cable to prevent an electrical spark should a tool or equipment come in contact with an exposed electrical terminal. Failure to follow these precautions may result in personal injury and/or damage to
the vehicle or its components.
in General Information.
- Remove the spark plug wires. Refer to Spark Plug Wires in Engine
Electrical.
- Disconnect the wiring harness from the clips, and move aside.
- Remove the following components for access to the right valve
rocker arm cover:
• | The crankcase vent hose |
• | The oil level indicator tube bracket. |
• | The air cleaner intake duct. Refer to Air Cleaner (Assembly)
in Engine Controls. |
- Remove the following components for access to the left valve rocker
arm cover:
5.1. | The air conditioning compressor and lay aside. Refer to Compressor
in Heater, Ventilation, and Air Conditioning. |
5.2. | The EGR valve inlet pipe. |
5.3. | The PCV and the hose |
5.4. | The power brake vacuum pipe and move aside |
- Remove the valve rocker arm cover bolts.
- Remove the valve rocker arm cover and the gasket.
- Clean all traces of old gasket from the valve rocker arm cover
and the cylinder head.
- Inspect the valve rocker arm cover sealing surface for distortion.
Replace the valve rocker arm cover if necessary.
Installation Procedure
- Install a new valve rocker arm cover gasket.
- Install the valve rocker arm cover.
- Install the valve rocker arm cover bolts.
Tighten
Tighten the cover bolts to 12 N·m (106 lb in).
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the components as follows for the left valve rocker arm
cover:
4.1. | The air conditioning compressor and the bracket. Refer to Compressor
Replacement in Heater, Ventilation, and Air Conditioning. |
4.2. | The EGR valve inlet pipe. |
4.3. | The PCV and the hose |
4.4. | The power brake vacuum pipe |
- Install the components as follows for the right valve rocker arm
cover:
5.1. | The crankcase ventilation hose |
5.2. | The oil level indicator tube bracket. |
5.3. | The air cleaner intake duct. Refer to Air Cleaner (Assembly)
in Engine Controls. |
- Install the wiring harnesses to the valve rocker arm cover clips.
- Install the spark plug wires. Refer to Spark Plug Wire Replacement
in Engine Electrical.
- Connect the battery negative cable assembly to the battery negative
terminal.
Tighten
Tighten the bolt to 15 N·m (11 lb ft).