Tools Required
J 43181 Heater
Line Quick Connect Release Tool
Important: The surge tank outlet hose on the 4.3L, 6.6L, and 8.1L engines is part
of the radiator outlet hose and may not be serviced separately. The following
information applies only to the 4.8L, 5.3L, and 6.0L engines.
Removal Procedure
- Drain the cooling system.
Refer to
Cooling System Draining and Filling
.
- Loosen the air cleaner outlet duct clamps at the following locations:
• | Mass airflow/intake air temperature (MAF/IAT) sensor |
- Remove the radiator inlet hose clip from the outlet duct.
- Remove the air cleaner outlet duct.
- If equipped without regular
production option (RPO) C36 (auxiliary heater), remove the surge tank/heater
outlet hose (1) from the mounting clip.
- If equipped with RPO C36
(auxiliary heater), remove the surge tank/heater outlet hose (1) from the
mounting clip.
- Install the J 43181
to the surge tank outlet hose.
- Close the J 43181
around the surge tank outlet hose.
- Firmly pull the J 43181
into the quick connect end of the outlet hose.
- If equipped without RPO
C36 (auxiliary heater), firmly grasp the outlet hose. Pull the outlet hose
in order to disengage the hose from the heater and blower module.
- If equipped with RPO C36
(auxiliary heater), firmly grasp the outlet hose. Pull the outlet hose in
order to disengage the hose from the heater and blower module.
- Reposition the surge tank
outlet hose clamp at the surge tank.
- Remove the surge tank outlet hose (2) from the surge tank.
- Reposition the surge tank
outlet hose clamp at the water pump.
- Remove the surge tank outlet hose from the water pump.
- Remove the surge tank outlet hose.
Installation Procedure
- Install the surge tank
outlet hose.
- Install the surge tank outlet hose to the water pump.
- Position the surge tank outlet hose clamp to the water pump.
- Install the surge tank
outlet hose (2) to the surge tank.
- Position the surge tank outlet hose clamp to the surge tank.
- If equipped with RPO C36
(auxiliary heater), connect the surge tank outlet hose to the heater and blower
module.
- If equipped without RPO
C36 (auxiliary heater), connect the surge tank outlet hose to the heater and
blower module.
Firmly push the hose onto the heater and blower module pipe until an
audible click is heard.
- If equipped with RPO C36
(auxiliary heater), install the surge tank/heater outlet hose (1) to the mounting
clip.
- If equipped without RPO
C36 (auxiliary heater), install the surge tank/heater outlet hose (1) to the
mounting clip.
Important: Align the arrow at the throttle body end of the duct with the throttle
body attaching stud.
- Install the air cleaner outlet duct.
- Install the radiator inlet hose clip to the outlet duct.
- Tighten the air cleaner outlet duct clamps at the following locations:
Tighten
Tighten the air cleaner outlet duct clamp screws to 7 N·m
(62 lb in).
- Fill the cooling system. Refer to
Cooling System Draining and Filling
.