Cold Shift Pattern: Displays Enabled or Disabled. This parameter indicates whether
the transmission is operating under a cold shift strategy.
Current Gear: Displays 1, 2, 3, 4, or 5. This parameter indicates the current
commanded state of the shift solenoids.
Driver Demanded Engine Torque: Displays a range of 0-9999 lb ft. This parameter indicates
the amount of torque that is requested by throttle angle and driving conditions.
ECT (Engine Coolant Temperature): Displays a range of -40°C to 151°C (-40°F to 304°F).
This parameter is the input signal of the engine coolant temperature sensor.
Then engine coolant temperature is high (151°C) when the signal voltage
is low (0 V), and the engine coolant temperature is low (-40°C) when the
signal voltage is high (5 V).
Engine Run Time: Displays a range of 0:00:00-18:12:15 hr/min/sec. This parameter
measures how long the engine has been in operation during the present ignition
cycle.
Engine Torque: Displays a range of 0-9999 lb ft. This parameter is a calculated
value based on engine load, throttle position, mass air flow, and other engine
and transmission inputs. This parameter is accurate to within 15 ft/lb of
actual measured engine torque.
Forced Motor Solenoid A Enabled: Displays Yes or No. This parameter indicates the commanded state
of the pressure control solenoid A, reading Yes when the solenoid is energized
and No when de-energized.
Forced Motor Solenoid B Enabled: Displays Yes or No. This parameter indicates the commanded state
of the pressure control solenoid B, reading Yes when the solenoid is energized
and No when de-energized.
Gear Commanded: Displays a range from 0-8. This parameter indicates the commanded
gear state from the TCM (transmission control module). When the vehicle is
in the Park or Neutral position this parameter will display a 0. When the
vehicle is placed in Drive, this parameter will display 1 while the vehicle
is in first gear and change accordingly as the vehicle shifts through 2,3,4,
and 5.
Gear Ratio: Displays a range of 0.000 to 8.00:1. This parameter is the actual
gear ratio of the current commanded gear. In the current gear of R, D4, D3,
D2, D1, it is calculated by dividing the input speed by the output speed.
In the current gear of D5 with TCC locked, the gear ratio is calculated by
dividing the turbine speed by the output speed.
Gear Selected: Displays a range from 0-8. This parameter indicates the selected
state of the gear selector. Park = 8, Reverse = 7, Neutral = 0, Drive = 5,
3 = 3, 2 =2, 1 =1 as the gear selector is moved through the ranges.
Ignition Voltage: Displays a range from 0.0-25.5 Volts. This parameter indicates
the voltage level on the Ignition input to the TCM (transmission control module).
The normal ignition voltage is approximately 13.8 volts, but may vary between
11-16 volts.
Last Output Speed Range Shift: Displays a range from 0-8192 RPM. This parameter indicates
the RPM value at which the last shift occurred.
Next Output Speed for Downshift: Displays a range from 0-8192 RPM. This parameter indicates
the RPM value at which the next output speed downshift will occur based on
current driving requirements.
Next Output Speed Upshift: Displays a range from 0-8192 RPM. This parameter indicates
the RPM value at which the next output speed upshiftshift will occur based
on current driving requirements.
Normal Shift Pattern: Displays Enabled or Disabled. This parameter indicates that the
transmission is operating under a normal shift pattern strategy.
PC Sol. A Actual Current: Displays 0.00-1.1 amps. This parameter is the actual current
the pressure control A solenoid circuit at the control module.
PC Sol. A Ref. Current: Displays 0.00-1.1 amps. This parameter is the commanded current
of the pressure control A solenoid circuit at the control module.
PC Sol. B Actual Current: Displays 0.00-1.1 amps. This parameter is the actual current
the pressure control B solenoid circuit at the control module.
PC Sol. B Ref. Current: Displays 0.00-1.1 amps. This parameter is the commanded current
of the pressure control B solenoid circuit at the control module.
PC Sol. A Duty Cycle: Displays 0-100 percent. This parameter is the commanded state
of the pressure control A solenoid expressed as a percentage of energized
On time.
PC Sol. B Duty Cycle: Displays 0-100 percent. This parameter is the commanded state
of the pressure control B solenoid expressed as a percentage of energized
On time.
Previous Gear: Displays 0-7. This parameter displays the most recent gear
the transmission has completed. During an upshift or downshift it will continue
to display the gear it was currently in until the new gear position has been
successfully completed.
Requested Torque: Displays a range of 0-9999 lb ft. This parameter indicates
the amount of torque required by the driver.
Service Brake Status Inverted: Displays Enabled or Disabled. This parameter indicates the status
of the brake switch. Enabled indicates that the brake pedal is not depressed.
Disabled indicates that the brake pedal is depressed.
Shift Solenoid C: Displays On or Off. This parameter is the commanded state of the
shift solenoid C valve. On represents a commanded energized state (current
is flowing through the solenoid). Off represents a non-commanded state (current
is not flowing through the solenoid).
Shift Solenoid D: Displays On or Off. This parameter is the commanded state of the
shift solenoid D valve. On represents a commanded energized state (current
is flowing through the solenoid). Off represents a non-commanded state (current
is not flowing through the solenoid).
Shift Solenoid E: Displays On or Off. This parameter is the commanded state of the
shift solenoid E valve. On represents a commanded energized state (current
is flowing through the solenoid). Off represents a non-commanded state (current
is not flowing through the solenoid).
Shift Solenoid C Open/Short to GND: Displays Yes or No. This parameter indicates if an open or a short
to ground exists in the feedback signal from the shift solenoid C to the PCM.
Shift Solenoid C Short to Volts: Displays Yes or No. This parameter indicates if a short to B+ exists
in the feedback signal from the shift solenoid C to the PCM.
Shift Solenoid D Open/Short to GND: Displays Yes or No. This parameter indicates if an open or a short
to ground exists in the feedback signal from the shift solenoid D to the PCM.
Shift Solenoid D Short to Volts: Displays Yes or No. This parameter indicates if a short to B+ exists
in the feedback signal from the shift solenoid D to the PCM.
Shift Solenoid E Open/Short to GND: Displays Yes or No. This parameter indicates if an open or a short
to ground exists in the feedback signal from the shift solenoid E to the PCM.
Shift Solenoid E Short to Volts: Displays Yes or No. This parameter indicates if a short to B+ exists
in the feedback signal from the shift solenoid E to the PCM.
TCC Duty Cycle: Displays 0-100 percent. This parameter is the commanded percentage
of On time the TCC solenoid is energized. 90 percent represents an On (energized)
commanded state. 0 percent represents an Off (non-energized) commanded state.
TCC Duty Cycle Open/Short to GND: Displays Yes or No. This parameter indicates if an open or a short
to ground exits in the feedback signal from the TCC solenoid valve to the
PCM.
TCC Duty Cycle Short to Volts: Displays Yes or No. This parameter indicates if a short to B+ exits
in the feedback signal from the TCC solenoid valve to the PCM.
TCC Slip Speed: Displays -4080 to +4079 RPM. This parameter is the difference
between transmission input speed and engine speed. A negative value indicates
that the engine speed is less than the input speed (deceleration). A positive
value indicates that the engine value of zero indicates that the engine speed
is equal to the input speed (TCC is applied).
TFP Sw. C/D/E/R: Displays On/Off, On/Off, On/Off. This parameter indicates the state
of the three inputs from the automatic transmission fluid pressure manual
valve position switch assembly. On represents a 0 voltage signal. Off represents
a B+ voltage signal.
Torque Management Duty Cycle: Displays in a percent of Duty Cycle. This parameter indicates the
amount of torque management being used by the TCM (transmission control module).
Tow/Haul Mode: Displays Active/Inactive. This parameter indicates whether the
driver has placed the vehicle in the Tow/Haul mode. When this parameter is
active, the TCM modifies its shift strategy in order to provide more torque
to the wheels during shifts.
Torque Requested: Displays a range of 0-9999 lb ft. This parameter indicates
the amount of torque required by the driver.
TP Angle: Displays a range of 0-100 percent. The TP angle is computed
by the PCM from TP voltage. The TP angle should display 0 percent at idle
and 100 percent at wide open throttle (WOT).
TR Sw.: Displays a range of (Park, Reverse, Neutral, Drive, 4, 3, 2, 1).
The trans range (TR) switch indicates the trans range selected by the driver.
TR Sw. A/B/C/P: Displays On/Off, On/Off, On/Off, On/Off. These parameters are the
four inputs from the automatic transmission fluid pressure manual valve position
switch assembly. ON represents a 0 voltage signal. OFF represents a B+ voltage
signal.
Trans. Fluid Temp.: Displays -40°C to 151°C (-40°F to 304°F).
This parameter is the input signal of the transmission fluid temperature sensor.
The transmission fluid temperature is high when the signal voltage is low
(0 volts), and transmission fluid temperature is low when the signal voltage
is high (5 volts).
Transmission Hot Mode: Displays On or Off. This parameter monitors the transmission fluid
temperature. Yes indicates that the transmission fluid temperature has exceeded
135°C (275°F).
Transmission ISS: Displays 0-8192 RPM. This parameter measures the rotational
speed of the input shaft expressed as revolutions per minute.
Transmission OSS: Displays 0-8192 RPM. This parameter measures the rotational
speed of the transmission Output shaft expressed as revolutions per minute.
On four-wheel drive applications, the transfer case output shaft speed is
measured.
Turbine Speed: Displays 0-8192 RPM. This parameter indicates the rotational
speed of the torque convertor turbine shaft expressed as revolutions per minute.
In commanded gears 1, 2,3, and 4 the turbine speed equals the input speed.
4WD Low: Displays Enabled or Disabled. This parameter is the signal state
of the four-wheel drive low circuit. Enabled indicates a 0 voltage signal
requested 4WD low. Disabled indicates a B+ voltage signal which does not
request 4WD low.