HVAC -- Primary ECC Data -- Outside Air Temp: The
scan tool displays -40 to +60°C (-40 to +140°F). The output of
the ambient air temperature sensor.
HVAC -- Primary ECC Data -- Inside Air Temp: The scan
tool displays -40 to +60°C (-40 to +140°F). The output of the
inside air temperature sensor.
HVAC -- Primary ECC Data -- Upper Outlets Duct Temp: The scan tool displays -40 to +150°C (-40 to +300°F). The output
of the upper outlets duct temperature sensor.
HVAC -- Primary ECC Data --Lower Outlets Duct Temp: The scan tool displays -40 to +150°C (-40 to +300°F). The output
of the lower outlets duct temperature sensor.
HVAC -- Auxiliary ECC Data -- Aux. Inside Air Temp: The scan tool displays -40 to +150°C (-40 to +300°F). The output
of the Aux. inside air temperature sensor.
HVAC -- Auxiliary ECC Data --Aux. Upper Outlet Temp: The scan tool displays -40 to +150°C (-40 to +300°F). The output
of the Aux. Upper Outlet temperature sensor.
HVAC -- Auxiliary ECC Data --Aux. Lower Outlet Temp: The scan tool displays -40 to +150°C (-40 to +300°F). The output
of the Aux. Lower Outlet temperature sensor.
HVAC -- Primary ECC Data -- Solar Sensor: The scan
tool displays 0-250 counts. The solar load output of the sunload sensor.
HVAC -- Primary ECC Data -- Blower Motor PWM Speed: The scan tool displays 0-98%.
HVAC --Auxiliary ECC Data --Auxiliary Blower Motor PWM: The scan tool displays 0-98%.
HVAC -- Primary ECC Data -- Mode Selection Position: The scan tool displays AUTO, Upper, Defog, Bi-Level, Heater or Defrost. The current
operating mode of the HVAC system.
HVAC -- Primary ECC Data -- A/C Request: The scan
tool displays Yes or No.
HVAC -- Primary ECC Data -- A/C LED On : The scan
tool displays on or off.
HVAC -- Primary ECC Data --Recirc LED: The scan tool
displays on or off.
HVAC -- Primary ECC Data --Outside Air LED: The scan
tool displays on or off.
HVAC -- Primary ECC Data --Rear Defog: The scan tool
displays on or off.
HVAC --Primary ECC Data --Mode Door Actual: The scan
tool displays 0-255 counts. The signal output from the feedback pot
on the actuator.
HVAC --Primary ECC Data -- Mode Door Commanded: The scan tool displays 0-255 counts. The desired position of the actuator.
HVAC --Primary ECC Data -- Mode Door Max. Position: The scan tool displays 0-255 counts. The maximum travel range when driven
to the door stop during a recalibration.
HVAC --Primary ECC Data -- Mode Door Min. Position: The scan tool displays 0-255 counts. The minimum travel range
when driven to the door stop during a recalibration.
HVAC --Auxiliary ECC Data --Aux. Mode Door Actual: The scan tool displays 0-255 counts. The signal output from the feedback
pot on the actuator.
HVAC --Auxiliary ECC Data --Aux. Mode Door Commanded: The scan tool displays 0-255 counts. The desired position of the
actuator.
HVAC --Auxiliary ECC Data --Aux. Mode Door Max. Position: The scan tool displays 0-255 counts. The maximum travel range when
driven to the door stop during a recalibration.
HVAC --Auxiliary ECC Data --Aux. Mode Door Min. Position: The scan tool displays 0-255 counts. The minimum travel range when
driven to the door stop during a recalibration.
HVAC -- Primary ECC Data-- Air Inlet Door Actual: The scan tool displays 0-255 counts. The signal output from the feedback
pot on the actuator.
HVAC --Primary ECC Data -- Air Inlet Door Commanded: The scan tool displays 0-255 counts. The desired position of the actuator.
HVAC --Primary ECC Data -- Air Inlet Door Max.: The scan tool displays 0-255 counts. The maximum travel range when driven
to the door stop during a recalibration.
HVAC --Primary ECC Data -- Air Inlet Door Min.: The scan tool displays 0-255 counts. The minimum travel range when driven
to the door stop during a recalibration.
HVAC -- Primary ECC Data --Air Mix Door Actual: The
scan tool displays 0-255 counts. The signal output from the feedback
pot on the actuator.
HVAC -- Primary ECC Data --Air Mix Door Commanded: The scan tool displays 0-255 counts. The desired position of the actuator.
HVAC -- Primary ECC Data --Air Mix Door Max. Position: The scan tool displays 0-255 counts. The maximum travel range when
driven to the door stop during a recalibration.
HVAC -- Primary ECC Data --Air Mix Door Min. Position: The scan tool displays 0-255 counts. The minimum travel range when
driven to the door stop during a recalibration.
HVAC --Auxiliary ECC Data --Aux. Mix Door Actual: The scan tool displays 0-255 counts. The signal output from the feedback
pot on the actuator.
HVAC --Auxiliary ECC Data --Aux. Mix Door Commanded: The scan tool displays 0-255 counts. The desired position of the actuator.
HVAC --Auxiliary ECC Data --Aux. Mix Door Max. Position: The scan tool displays 0-255 counts. The maximum travel range when
driven to the door stop during a recalibration.
HVAC --Auxiliary ECC Data --Aux. Mix Door Min. Position: The scan tool displays 0-255 counts. The minimum travel range when
driven to the door stop during a recalibration.
HVAC -- Miscellaneous Tests -- Instant OAT Update: The scan tool displays Commanded State: None or On. Updates the ECC outside air temperature
input to the current raw value.
HVAC -- Miscellaneous Tests -- Blower Motor: The scan
tool displays Commanded State: None, Off or On. This function allows you to command
the blower motor to its maximum (100%) or minimum (0%) speeds.
HVAC --Special Functions--Set Up New HVAC: This function
has the ECC relearn a new heater and A/C control.
PCM -- A/C Information -- A/C Clutch Feedback Signal: The scan tool displays On or Off. On is displayed when the PCM has energized the
A/C clutch relay.
PCM -- Engine Data 1 -- ECT: The scan tool displays -40
to +215°C (-40 to +420°F). The output of the engine coolant temperature
sensor.
PCM -- Engine Data 2 -- ECT: The scan tool displays -40
to +215°C (-40 to +420°F). The output of the engine coolant temperature
sensor.
PCM -- Engine Data 2 -- Commanded A/C: The scan tool
displays On or Off. On is displayed when the PCM has energized the A/C clutch relay.
PCM -- Engine Data 2 -- A/C Compressor Cycling Switch: The scan tool displays Normal and Low Pressure. The output of the A/C pressure
sensor.
PCM -- Engine Data 2 -- A/C Request Signal: The scan
tool displays Yes or No. Yes is displayed when the HVAC control module is requesting
the PCM to turn on the compressor clutch.
PCM -- Engine Data 2 -- A/C High Pressure Recirculation Switch: The scan tool displays OK or Low Pressure. Displays the output of the High
Pressure Recirculation Switch.