Radiator Surge Tank Outlet Hose/Pipe Replacement 4.8L, 5.3L, and 6.0L Engines
Special Tools
J 43181
Heater Line Quick Connect Release Tool
Removal Procedure
- Drain the cooling system. Refer to
Cooling System Draining and Filling.
- Loosen the air cleaner outlet duct clamps at the following locations:
• | Mass airflow/intake air temperature (MAF/IAT) sensor |
- Remove the air cleaner outlet duct.
- If equipped without regular production option (RPO) C36 auxiliary heater, remove the surge tank/heater outlet
hose (1) from the mounting clip.
- If equipped with RPO C36 auxiliary heater, remove the surge tank/heater outlet
hose (1) from the mounting clip.
- Install the
J 43181
to the surge tank outlet hose (black connector).
- Close the
J 43181
around the surge tank outlet hose.
- Firmly pull the
J 43181
into the quick connect end of the outlet hose.
- If equipped without RPO C36 auxiliary heater, firmly grasp the outlet hose. Pull the outlet hose in order
to disengage the hose from the heater and blower module.
- If equipped with RPO C36 auxiliary heater, firmly grasp the outlet hose. Pull
the outlet hose in order to disengage the hose from the heater and blower module.
- Reposition the surge tank outlet hose clamp at the surge tank.
- Remove the surge tank outlet hose (2) from the surge tank.
- Reposition the surge tank outlet hose clamp at the water pump.
- Remove the surge tank outlet hose from the water pump.
- Remove the surge tank outlet hose.
Installation Procedure
- Install the surge tank outlet hose.
- Install the surge tank outlet hose to the water pump.
- Position the surge tank outlet hose clamp to the water pump.
- Install the surge tank outlet hose (2) to the surge tank.
- Position the surge tank outlet hose clamp to the surge tank.
- If equipped with RPO C36 auxiliary heater, connect the surge tank outlet hose
to the heater and blower module.
- If equipped without RPO C36 auxiliary heater, connect the surge tank outlet hose to the heater and blower
module.
Firmly push the hose onto the heater and blower module pipe until an audible click is heard.
- If equipped with RPO C36 auxiliary heater, install the surge tank/heater outlet
hose (1) to the mounting clip.
- If equipped without RPO C36 auxiliary heater, install the surge tank/heater outlet hose (1) to the mounting
clip.
- Install the air cleaner outlet duct.
Notice: Refer to Fastener Notice in the Preface section.
- Align the arrow at the throttle body end of the duct with the throttle body attaching
stud.
- Tighten the air cleaner outlet duct clamps at the following locations:
Tighten
Tighten the clamps to 7 N·m (62 lb in).
- Fill the cooling system. Refer to
Cooling System Draining and Filling.