Removal Procedure
- Remove the retaining bolts.
- Remove the insulator (1) from the HVAC module by pulling downwards.
Installation Procedure
- Install the insulator (1) to the HVAC module.
Notice: Refer to Fastener Notice in the Preface section.
- Install the retaining bolts.
Tighten
Tighten the bolts to 1.6 N·m (14 lb in).