The number(s) below refer to the step number(s) on the diagnostic table.
This step determines if the transfer case shift control module has electronic control of the Service Indicator.
This step determines if there is an internal short to ground in the transfer case shift control module.
This step determines if CKT 1567 is shorted to ground.
Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Was the Transfer Case Diagnostic System Check performed? | -- | Go to Step 2 | |
Does the Service Indicator turn Off? | -- | Go to Step 7 | Go to Step 3 | |
Disconnect both connectors at the transfer case shift control module. Does the Service Indicator turn Off? | -- | Go to Step 7 | Go to Step 4 | |
Is the resistance within the specified value? | OL | Go to Step 5 | Go to Step 6 | |
5 | Service Instrument Cluster for short to ground condition. Is the action complete? | -- | Go to Step 8 | -- |
6 | Repair a short to ground in CKT 1567. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | Go to Step 8 | -- |
7 | Replace the transfer case shift control module. Refer to Transfer Case Shift Control Module Replacement . Is the action complete? | -- | Go to Step 8 | -- |
8 |
Have all the ATC components been reconnected and properly mounted? | -- | Go to Step 9 | -- |
9 | Clear all ATC DTCs. Have all the ATC DTCs been cleared? | -- | -- |