The auxiliary air temperature actuator is an electronic device that incorporates a stepper motor and feedback potentiometer. The position of the auxiliary air temperature actuator is based on the auxiliary air temperature door position signal voltage from the potentiometer. The rear auxiliary HVAC module converts this voltage to a digital signal that can be transmitted over the keyboard display driver (KDD) data bus to the HVAC control module. The HVAC control module contains the logic that controls the operation of the auxiliary air temperature actuator. When a change in air temperature is required (greater than 4 counts) the HVAC control module will drive the air temperature actuator in the appropriate direction to achieve the desired setting while comparing the actual position to the commanded position. If the actual value differs from the commanded value by 4 or more counts, the actuator is considered stalled and the DTC will set.
• | The ignition is ON. |
• | Ignition voltage is between 9-16 volts. |
• | An actuator positional change is attempted. |
The actual air mix door position differs from the commanded air mix door position by 4 counts or more.
The actuator is considered stalled and the HVAC control module will command the actuator to stop rotation (2.5 V).
• | If the HVAC control no longer detects a failure, then the DTC will become history. |
• | The history DTC will clear after 50 ignition cycles without a failure. |
• | The DTC can be cleared with a scan tool. |
• | A dead zone exists in a range 10 counts above or below the mix door max or mix door min positions. When the air mix door actual data parameter is within the dead zone, the DTC will not set. If the air mix door commanded data parameter differs from the air mix door actual data parameter by 4 counts or more outside the dead zone, the DTC will set. |
• | A damaged or broken auxiliary air temperature door and or actuator can cause this DTC to set. |
• | If none of the above conditions exist refer to Testing for Intermittent Conditions and Poor Connections in Wiring Systems. |
Step | Action | Value(s) | Yes | No | ||||||
---|---|---|---|---|---|---|---|---|---|---|
Schematic Reference: HVAC Air Delivery/Temperature Control Schematics | ||||||||||
1 | Did you perform the HVAC Diagnostic System Check? | -- | Go to Step 2 | Go to Diagnostic System Check | ||||||
2 |
Does the scan tool indicate that the Aux. Mix Door Commanded data parameter is within the specified value of the Aux. Mix Door Actual data parameter? | 0-3 counts | Go to Diagnostic Aids | Go to Step 3 | ||||||
3 |
Does the Aux. Mix Door Actual data parameter change at all? | -- | Go to Step 9 | Go to Step 4 | ||||||
4 | Test the ignition 3 voltage circuit of the auxiliary air temperature actuator for an open or a high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 14 | Go to Step 5 | ||||||
5 | Test the 5 volt reference circuit of the auxiliary air temperature actuator for an open, high resistance, short to ground or short to voltage. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 14 | Go to Step 6 | ||||||
6 | Test the auxiliary air temperature door control circuit of the auxiliary air temperature actuator for an open, high resistance, short to ground or short to voltage. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 14 | Go to Step 7 | ||||||
7 | Test the 5 volt reference circuit of the front auxiliary HVAC control assembly for a short to voltage. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 14 | Go to Step 8 | ||||||
8 |
Important: The auxiliary air temperature actuator connector and the rear HVAC control module connector must be connected to correctly perform test.
Does the auxiliary air temperature actuator drive shaft rotate and do the counts change? | -- | Go to Step 11 | Go to Step 10 | ||||||
9 | Inspect the auxiliary air temperature door and the auxiliary air temperature actuator for the following:
Did you find and correct the condition? | -- | Go to Step 14 | Go to Diagnostic Aids | ||||||
10 | Inspect for poor connections at the harness connector of the auxiliary air temperature actuator. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 14 | Go to Step 12 | ||||||
11 | Inspect for poor connections at the harness connector of the rear HVAC control module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 14 | Go to Step 13 | ||||||
12 | Replace the auxiliary air temperature actuator. Refer to Temperature Actuator Replacement - Auxiliary . Did you complete the replacement? | -- | Go to Step 14 | -- | ||||||
13 | Replace the rear HVAC control module. Refer to Control Assembly Replacement - Auxiliary . Did you complete the replacement? | -- | Go to Step 14 | -- | ||||||
14 |
Does the DTC reset? | -- | Go to Step 2 | System OK |