Danger: In order to reduce the risk of personal injury, loss of high voltage isolation to ground and higher system impedance, do not attempt to repair any HV wiring, connector, or terminal that is damaged. High voltage coaxial type cables are not repairable. Never attempt to repair a coaxial type cable. The entire cable/harness or component must be replaced. In order to maintain system integrity and personal safety, never attempt to repair any high voltage wiring, cables, or terminals. Performing this procedure on high voltage circuits may result in serious injury or death.
If the conductive portion of the wire is not damaged, locate the problem and apply tape around the wire. If the damage is more extensive, replace the faulty segment of the wire. Refer to Splicing Copper Wire Using Splice Clips and follow the instruction to repair the wire.
Metric Wire Sizes (mm 2) | AWG Sizes |
---|---|
0.13 | 26 |
0.21 | 24 |
0.32 | 22 |
0.52 | 20 |
0.83 | 18 |
1.31 | 16 |
2.09 | 14 |
3.31 | 12 |
5.27 | 10 |
8.37 | 8 |
13.3 | 6 |
21.2 | 4 |
33.6 | 2 |
53.5 | 1/0 |