Suction Hose Replacement for Chevrolet Tracker - 2WD 1998
Removal Procedure
- Discharge and recover the refrigerant. Refer to Refrigerant Recovery and Recharging
.
- Remove the bolt and the
compressor suction hose at the compressor (4).
- Disconnect the compressor suction hose pipe fitting (3)
above the radiator.
Installation Procedure
- Coat new O-rings with
525 viscosity mineral oil.
- Install the new O-rings to the refrigerant pipe fittings.
- Connect the compressor suction hose pipe fitting (3) above
the radiator.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
Tighten
Tighten the compressor suction hose pipe fitting to 45 N·m
(33 lb ft)
- Install the compressor suction hose at the compressor (4).
Secure with 1 bolt.
Tighten
Tighten the bolt to 10 N·m (89 lb in)
- Evacuate and recharge the air conditioning system. Refer to Refrigerant Recovery and Recharging
.
- Operate the A/C system and test for refrigerant leaks. Refer to
Leak Testing
.