Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
DEFINITION: All chimes appear to be inoperative. | ||||
1 | Did you review the audible warnings operation and perform the necessary inspections? | -- | Go to Step 2 | |
2 |
Did all of the chimes operate normally? | -- | Go to Testing for Intermittent Conditions and Poor Connections | Go to Step 3 |
3 | Is the remainder of the instrument cluster operating normally? | -- | Go to Step 7 | Go to Step 4 |
4 | Test the ground circuit at terminal 10 of instrument cluster connector C2 for an open. Did you find and correct the condition? | -- | Go to Step 8 | Go to Step 5 |
5 | Test the ignition positive voltage circuit at terminal 14 of C1 for an open. Did you find and correct the condition? | -- | Go to Step 8 | Go to Step 6 |
6 | Repair/replace the instrument cluster printed circuit. Refer to Flat Wire Repairs in Wiring Systems or Printed Instrument Cluster Circuit Replacement . Did you complete the repair/replacement? | -- | Go to Step 8 | -- |
7 | Replace the multifunction alarm. Refer to Multifunction Alarm Module Replacement . Did you complete the replacement? | -- | Go to Step 8 | -- |
8 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 3 |