Removal Procedure
- Loosen the hose clamp (1) for the
positive crankcase ventilation (PCV) valve .
- Remove the intake manifold vacuum hose (3) from the PCV valve.
- Remove the PCV valve from the valve cover (2).
Installation Procedure
- Install the PCV valve into the valve cover (2).
- Connect the intake manifold vacuum hose (3) to the PCV valve.
- Secure the PCV valve with the hose clamp (1).