Step | Action | Yes | No |
---|---|---|---|
1 | Did you review the Instrument Cluster Description and Operation and perform the necessary inspections? | Go to Step 2 | |
2 | Verify that the instrument cluster gages are inoperative. Do the gages operate normally? | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
3 |
Does an open condition exist? | Go to Step 4 | Go to Step 5 |
4 | Repair the open in the BLK/WHT wire between the instrument cluster and the junction block C4 cavity 1. Did you complete the repair? | Go to Step 9 | -- |
5 |
Does an open condition exist? | Go to Step 6 | Go to Step 7 |
6 | Repair the short in the BLK/YEL wire between the instrument cluster and G103. Did you complete the repair? | Go to Step 9 | -- |
7 | Inspect the instrument cluster for any damage to the cluster or printed circuit. Is there any damage to the instrument cluster or printed circuit? | Go to Step 8 | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems |
8 | Repair or replace the instrument cluster or printed circuit. Did you complete the repair? | Go to Step 9 | -- |
9 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 3 |