Step | Action | Yes | No |
---|---|---|---|
1 | Did you review the Instrument Cluster Description and Operation and perform the necessary inspections? | Go to Step 2 | |
2 | Verify that the oil gage indicator is inoperative. Does the oil gage indicator operate normally? | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
3 |
Does the oil pressure indicator light? | Go to Step 4 | Go to Step 5 |
4 | Replace the oil pressure switch. Did you complete the repair? | Go to Step 8 | -- |
5 |
Is a short to ground or open condition present? | Go to Step 6 | Go to Step 7 |
6 | Repair the open in the YEL/BLK wire between the instrument panel cluster assembly and the oil pressure switch. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 8 | -- |
7 | Repair or replace the instrument panel cluster printed circuit. Refer to Printed Instrument Cluster Circuit Replacement . Is the repair complete? | Go to Step 8 | -- |
8 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 3 |