Step  | Action  | Value(s)  | Yes  | No  | 
|---|---|---|---|---|
1  | Was the HVAC Blower Controls System Check performed?  | --  | Go to Step 2  | Go to HVAC System Check  | 
2  | Backprobe the blower speed selector switch connector with a test lamp from cavity 1 to chassis ground. Does the test lamp light?  | --  | Go to Step 4  | Go to Step 3  | 
3  | Repair the open in the LT GRN wire between fuse block 2 and the blower speed selector switch. Refer to Wiring Repairs in Wiring Systems. Is the repair complete?  | --  | Go to HVAC System Check  | --  | 
4  | 
 Does the test lamp light?  | --  | Go to Step 6  | Go to Step 5  | 
5  | Replace the blower speed selector switch. Refer to Blower Switch Replacement . Is the repair complete?  | --  | Go to HVAC System Check  | --  | 
6  | Backprobe the blower motor connector with a test lamp from cavity 2 to chassis ground. Does the test lamp light?  | --  | Go to Step 8  | Go to Step 7  | 
7  | Repair the open in the PNK wire between the blower motor and the blower speed selector switch. Refer to Wiring Repairs in Wiring Systems. Is the repair complete?  | --  | Go to HVAC System Check  | --  | 
8  | 
 Is the resistance less than the specified value?  | 3 ohms  | Go to Step 9  | Go to Step 10  | 
9  | Replace the blower motor. Refer to Blower Motor and Fan Replacement . Is the repair complete?  | --  | Go to HVAC System Check  | --  | 
10  | Repair the open in the BLK wire between the blower motor and G201. Refer to Wiring Repairs in Wiring Systems. Is the repair complete?  | --  | Go to HVAC System Check  | --  |