Step | Action | Yes | No | ||||
---|---|---|---|---|---|---|---|
1 | Was the Function Test performed? | Go to Step 2 | Go to Function Test | ||||
2 |
Is there airflow through the vent outlets at ambient temperature and no airflow through the heater, defroster and side window defroster outlets? | Go to Step 3 | Go to Step 5 | ||||
3 |
Is there hot airflow through the heater outlet at the blower high speed, minimum of hot airflow through the defroster and the side window defroster outlets and no airflow at the vent outlets? | Go to Step 4 | Go to Step 5 | ||||
4 |
Is there hot airflow through the defroster outlet and the side window defroster outlets at the blower at high speed, minimum hot airflow through the heater outlet and no airflow at the vent outlets? | -- | Go to Step 5 | ||||
5 |
Are the door travel and effort correct? | Go to Step 6 | Go to Step 8 | ||||
6 | Test the control cable(s) travel by moving the corresponding control at the heater control unit. Is the control cable travel correct? | Go to Step 7 | Go to Step 9 | ||||
7 | Inspect the control cable(s) attachment at the heater control unit. Repair as necessary. Refer to Control Assembly Replacement . Is the repair complete? | Go to Function Test | -- | ||||
8 | Repair the affected door at the heater case as necessary. Refer to Heater Case Replacement . Is the repair complete? | Go to Function Test | -- | ||||
9 | Repair or replace the affected control cable(s) as necessary. Refer to the following:
Is the repair complete? | Go to Function Test | -- |