Removal Procedure
- Open the instrument panel
(IP) compartment.
- Push in the left and right side of the IP compartment and lower
the IP compartment.
- Disconnect the blower
motor resistor electrical connector (2).
- Remove the screw from the blower case.
- Remove the blower motor resistor from the blower case.
Installation Procedure
- Install the blower motor
resistor to the blower case.
- Secure the resistor with the screw.
- Connect the blower motor resistor electrical connector (2).
- Close the instrument panel compartment.