Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: Keyless Entry Schematics DEFINITION: This table diagnoses the power door locks are operative using the power door lock switches and inoperative using the remote keyless entry. | |||
1 | Did you review the Keyless Entry System Description and Operation and perform the necessary inspections? | Go to Step 2 | Go to Symptoms - Keyless Entry |
2 | Verify that the power doors work from the power door switches and not from the Remote Keyless Entry Fob. Does the RKE Fob operate the door locks? | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
3 |
Does the system respond properly? | Go to Step 6 | Go to Step 4 |
4 |
Was there an open or short to ground condition in the PNK/WHT wire? | Go to Step 5 | Go to Step 7 |
5 | Repair the open or short to ground condition in the PNK/WHT wire between cavity L of the remote control door lock receiver and cavity 8 of the data link connector (DLC). Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 8 | -- |
6 |
Is the replacement complete? | Go to Step 8 | -- |
7 | Replace the remote control door lock receiver. Refer to Remote Control Door Lock Receiver Replacement . Is the replacement complete? | Go to Step 8 | -- |
8 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 3 |