Important: Do not use the intake manifold-to-cylinder head sealing gaskets again.
• | Clean the intake manifold gasket surfaces. |
• | Clean the intake manifold internal passages. |
Caution: Refer to Safety Glasses Caution in the Preface section.
11.1. | Locate a straight edge across the intake manifold cylinder head deck surface. |
Position the straight edge across a minimum of two runner port openings.
11.2. | Insert a feeler gage between the intake manifold and the straight edge. |
A intake manifold with warpage in excess of 3 mm (0.118 in) over a 200 mm (7.87 in) area is warped and should be replaced.
Notice: Refer to Fastener Notice in the Preface section.
Tighten
Tighten the EVAP solenoid bolt to 10 N·m (89 lb in).