Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: Exterior Lights Schematics Connector End View Reference: Lighting Systems Connector End Views | |||
1 | Did you perform the Lighting Systems Diagnostic System Check? | Go to Step 2 | |
2 | Verify that the front park lamps are inoperative. Do the park lamps operate normally? | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
3 | Inspect the F PARK fuse in the body relay block. Is the fuse open? | Go to Step 5 | Go to Step 4 |
4 | Inspect the inoperative bulbs/sockets for open or shorted filaments/terminals. Does any lamp have an open or shorted filament/terminals? | Go to Step 7 | Go to Step 6 |
5 | Repair the short to ground in the front park lamps supply voltage circuit or cornering lamps supply voltage circuit. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 8 | -- |
6 | Repair the open or high resistance in the front park lamps supply voltage circuit or ground circuit to the inoperative lamp. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 8 | -- |
7 | Replace the defective bulb/socket. Refer to Park/Turn Signal/Side Marker Lamp Bulb Replacement . Did you complete the repair? | Go to Step 8 | -- |
8 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 3 |