GM Service Manual Online
For 1990-2009 cars only

Secondary Fluid Pump Assembly Specifications M33 Only

Secondary Fluid Pump Assembly Specifications (M33 Only)

Application

Specification

Metric

English

Pump

  • Type

Gerotor - Internal/External Gear

  • Weight

0.589 kg

1.3 lb

  • Pump Deliver

2.5 lpm +/-0.1 @ 93.3°C (200°F)

0.5-1.3 gpm +/-0.026 @ 93.3°C (200°F)

  • Pressure

110.3-275.7 kPa +/-3.44

16-40 psi +/-0.5

Relief Pressure

  • Minimum

550 kPa

79.7 psi

  • Maximum

900 kPa

130.5 psi

Operating Temperature

  • Minimum

21°C

69.8°F

  • Maximum

104°C

219.2°F

Motor

Operating Voltage

  • Maximum

14.5 Volts

  • Minimum

11 Volts

  • Operating Range

14.5-13.5 Volts

  • Maximum Current

10 amp

  • Nominal Current Load

4.464 amp

  • Terminal/Winding Resistance

0.0-0.937 ohms