Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: Exterior Lights Schematics Connector End View Reference: Lighting Systems Connector End Views | |||
1 | Did you review the Exterior Lighting Systems Description and Operation and perform the necessary inspections? | Go to Step 2 | |
2 | Verify that the hazard lamps are always ON. Do the hazard lamps operate normally? | Go to Testing for Intermittent Conditions and Poor Connections | Go to Step 3 |
3 |
Is a ground signal present? | Go to Step 4 | Go to Step 5 |
4 | Test the multifunction turn signal switch hazard switch signal circuit for a short to ground. Refer to Circuit Testing and Wiring Repairs . Did you find and correct a condition? | Go to Step 9 | Go to Step 6 |
5 | Inspect for poor connections at the harness connector of the hazard/turn flasher. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | Go to Step 9 | Go to Step 7 |
6 | Inspect for poor connections at the harness connector of the multifunction turn signal switch. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | Go to Step 9 | Go to Step 8 |
7 | Replace the hazard/turn flasher. Refer to Hazard and Turn Signal Flasher Replacement . Did you complete the repair? | Go to Step 9 | -- |
8 | Replace the multifunction turn signal switch. Refer to Turn Signal Multifunction Switch Replacement . Did you complete the repair? | Go to Step 9 | -- |
9 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 3 |