Important:
• | If replacing the BCM with a GM Service Parts Operations (SPO) replacement part, the module will learn Passlock™ sensor data code immediately. The existing PCM however, must learn the new fuel continue password when the BCM is replaced. |
• | If replacing a PCM with a GM SPO replacement part, after programming, these modules will learn the incoming fuel continue password immediately upon receipt of a password message. Once a password message is received, and a password is learned, a learn
procedure must be performed to change this password again. A PCM which has been previously installed in another vehicle will have learned the other vehicle's fuel continue password, and will require a learn procedure after programming to learn the current vehicle's
password. |
Conditions
Use this procedure after replacing:
Learn Procedures
There are 2 available methods to perform the programming procedure:
• | A 10-minute procedure which requires a Tech 2 and a techline terminal. |
• | A 30-minute procedure which does not require the use of any tools. |
10-Minute Learn Procedure
Tools Required
• | Techline terminal with current Service Programming System (SPS) software |
- Connect the Tech 2 to the vehicle.
- Select "Request Information" under "Service Programming".
- Disconnect the Tech 2 from the vehicle and connect it to a Techline terminal.
- On the techline terminal, select "V.T.D. - Vehicle Theft Deterrent Learn" under Service Programming".
- Disconnect the Tech 2 from the Techline terminal and connect it to the vehicle.
- Turn ON the ignition, with the engine OFF.
- Select "Program ECU" under "Service Programming".
- At this time you will receive a screen on the Tech 2 stating to "PLEASE WAIT-MINUTES REMAINING 10".
- Turn OFF the ignition, and wait 30 seconds.
- Turn ON the ignition, with the engine OFF. The vehicle has now learned the password.
- With the Tech 2 (scan tool), clear any DTCs.
30-Minute Learn Procedure
Important: Do not remove the key from the ignition during this procedure. If the key is removed, the procedure will have to be performed from the beginning.
- Turn ON the ignition, with the engine OFF.
- Attempt to start the engine, then release the key to ON. The vehicle will not start.
- Observe the SECURITY telltale. After approximately 10 minutes, the telltale will turn OFF.
- Turn OFF the ignition, and wait 5 seconds.
- Repeat steps 1-4 two more times for a total of 3 cycles/30 minutes. The vehicle is now ready to relearn the Passlock™ Sensor Data Code and/or passwords on the next ignition switch transition from OFF to RUN.
Important: The vehicle learns the Passlock™ Sensor Data Code and/or password on the next ignition switch transition from OFF to RUN. You must turn the ignition OFF before attempting to start the vehicle.
- Start the engine. The vehicle has now learned the Passlock™ Sensor Data Code and/or password.
- With a scan tool, clear any DTCs if needed. History DTCs will self clear after 100 ignition cycles.