Step  | Action  | Yes  | No  | 
|---|---|---|---|
Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views DEFINITION: The blower motor is inoperative in all speed positions.  | |||
1  | Did you perform the Diagnostic System Check - Vehicle?  | Go to Step 2  | |
2  | 
 Does the blower motor operate in any of the speed positions?  | Go to Blower Motor Malfunction  | Go to Step 3  | 
3  | 
 Does the test lamp illuminate?  | Go to Step 10  | Go to Step 4  | 
4  | 
 Does the test lamp illuminate?  | Go to Step 8  | Go to Step 5  | 
5  | Connect a test lamp between the battery positive voltage circuit of the blower motor control processor and a good ground. Does the test lamp illuminate?  | Go to Step 7  | Go to Step 6  | 
6  | Repair the battery positive voltage circuit of the blower motor control processor. Refer to Wiring Repairs . Did you find and correct the condition?  | Go to Step 16  | --  | 
7  | Repair the ground circuit of the blower motor control processor. Refer to Wiring Repairs . Did you complete the repair?  | Go to Step 16  | --  | 
8  | 
 Does the test lamp increase intensity when the blower speed is increased?  | Go to Step 11  | Go to Step 9  | 
9  | Test the blower motor speed control circuit of the blower motor control processor for an open, short to ground, or short to voltage. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition?  | Go to Step 16  | Go to Step 12  | 
10  | Inspect for poor connections at the harness connector of the blower motor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition?  | Go to Step 16  | Go to Step 13  | 
11  | Inspect for poor connections at the harness connector of the blower motor control processor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition?  | Go to Step 16  | Go to Step 14  | 
12  | Inspect for poor connections at the harness connector of the HVAC control module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition?  | Go to Step 16  | Go to Step 15  | 
13  | Replace the blower motor. Refer to Blower Motor Replacement . Did you complete the replacement?  | Go to Step 16  | --  | 
14  | Replace the blower motor control processor. Refer to Blower Motor Control Processor Replacement . Did you complete the replacement?  | Go to Step 16  | --  | 
15  | Replace the HVAC control module. Refer to Control Module References for replacement, setup, and programming. Did you complete the replacement?  | Go to Step 16  | --  | 
16  | Operate the system in order to verify the repair. Did you correct the condition?  | System OK  | Go to Step 2  |