Step | Action | Yes | No | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views DEFINITION: Air recirculation is inoperative or is always ON. | |||||||||||||||
1 | Did you perform the Diagnostic System Check - Vehicle? | Go to Step 2 | |||||||||||||
2 |
Does the scan tool indicate that the Recirculate Switch parameter changes state? | Go to Step 3 | Go to Step 10 | ||||||||||||
3 |
Does the recirculation door move from the recirculation position to the outside air position? | Go to Testing for Intermittent Conditions and Poor Connections | Go to Step 4 | ||||||||||||
4 |
Does recirculation door move? | Go to Step 10 | Go to Step 5 | ||||||||||||
5 |
Does the test lamp illuminate? | Go to Step 6 | Go to Step 11 | ||||||||||||
6 | Test the ground circuit of the recirculation actuator for an open or high resistance. Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | Go to Step 14 | Go to Step 7 | ||||||||||||
7 | Test the recirculation door control circuit of the recirculation actuator for the following:
Refer to Circuit Testing and Wiring Repairs . Did you find and correct the condition? | Go to Step 14 | Go to Step 8 | ||||||||||||
8 | Inspect the recirculation door and the recirculation actuator for the following conditions:
Did you find and correct the condition? | Go to Step 14 | Go to Step 9 | ||||||||||||
9 | Inspect for poor connections at the harness connector of the recirculation actuator. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | Go to Step 14 | Go to Step 12 | ||||||||||||
10 | Inspect for poor connections at the harness connector of the HVAC control module. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs . Did you find and correct the condition? | Go to Step 14 | Go to Step 13 | ||||||||||||
11 | Repair the ignition 3 voltage circuit of the recirculation actuator. Refer to Wiring Repairs . Did you complete the repair? | Go to Step 14 | -- | ||||||||||||
12 | Replace the recirculation actuator. Refer to Recirculation Actuator Replacement . Did you complete the replacement? | Go to Step 14 | -- | ||||||||||||
13 | Replace the HVAC control module. Refer to Control Module References for replacement, setup, and programming. Did you complete the replacement? | Go to Step 14 | -- | ||||||||||||
14 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 3 |