• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
Headlamp Washer Switch Signal | B2697 | 1 | -- | -- |
Headlamp Washer Pump Relay Control | B3810 | B3810 | -- | -- |
Headlamp Washer Pump Control | 1 | 1 | 2 | -- |
Headlamp Washer Pump Ground | -- | 1 | -- | -- |
1. Headlamp washer pump inoperative 2. Headlamp washer pump always on |
Battery positive voltage is supplied to the coil and switch sides of the headlamp washer relay. The body control module (BCM) energizes the relay by grounding the relay coil through the relay control circuit. When the relay is energized, the relay switch is closed and battery positive voltage is supplied to the washer pump control circuit.
Headlamp Washer System Description and Operation
Control Module References for scan tool information
⇒ | If not the specified value, refer to Headlamp Washer Switch Circuit Test. |
⇒ | If greater than the specified range, test the ground circuit for an open/high resistance. |
⇒ | If not the specified value, test the signal circuit terminal H X2 for a short to ground. If the circuit tests normal, replace the BCM. |
⇒ | If not the specified value, test the signal circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the BCM. |
⇒ | If the test lamp illuminates, test the control circuit for a short to voltage. |
⇒ | If greater than the specified range, test the ground circuit for an open/high resistance. |
⇒ | If the headlamp washer pump does not activate, test the control circuit for an open/high resistance. If the circuit tests normal, test or replace the headlamp washer pump. |
⇒ | If the test lamp is always ON, test the relay control circuit for a short to ground. If the circuit tests normal, replace the BCM. |
⇒ | If the test lamp is always OFF, test the control circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the BCM. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for BCM replacement, programming, and setup |