Removal Procedure
- Remove the HVAC module assembly. Refer to
HVAC Module Assembly Replacement.
- Remove the screws retaining the recirculation assembly to the HVAC module assembly.
- Remove the screws from the recirculation actuator.
- Remove recirculation actuator.
- Remove the recirculation door (1) from the recirculation assembly.
Installation Procedure
- Install the recirculation door (1) to the recirculation assembly.
- Install the recirculation actuator.
Caution: Refer to Fastener Caution in the Preface section.
- Install the screws to the recirculation actuator and tighten to
1.9 N·m (18 lb in).
- Install the screws to assemble the recirculation assembly and tighten to
1.9 N·m (18 lb in).
- Install the HVAC module assembly. Refer to
HVAC Module Assembly Replacement.