Removal Procedure
- Remove the seal washer from the A/C refrigerant component.
Important: Cap or tape the open A/C refrigerant components immediately to prevent system contamination.
- Inspect the seal washer for signs of damage to help determine the root cause of the failure.
- Inspect the A/C refrigerant components for damage or burrs. Repair if necessary.
Important: DO NOT reuse sealing washer.
- Discard the sealing washer.
Installation Procedure
Important: Flat washer type seals do not require lubrication.
- Inspect the new seal washer for any signs of cracks, cuts, or damage.
Do not use a damaged seal washer.
- Remove the cap or tape from the A/C refrigerant components.
- Using a lint-free clean, dry cloth, clean the sealing surfaces of the A/C refrigerant components.
- Carefully install the new seal washer onto the A/C refrigerant component.
The washer must completely bottom against the surface of the fitting.
Important: After tightening the A/C components, there should be a slight sealing washer gap of approximately 1.2 mm (3/64 in) between the A/C line and the A/C component.
- Assemble the remaining A/C refrigerant components. Refer to the appropriate repair procedure.