Removal Procedure
- Remove the HVAC module assembly. Refer to
HVAC Module Assembly Replacement.
- Remove the air inlet assembly screws.
- Remove the air inlet assembly.
- Remove the recirculation actuator screws.
- Remove the electrical connector from the recirculation actuator.
- Remove the recirculation actuator.
Installation Procedure
- Install the recirculation actuator.
Caution: Refer to Fastener Caution in the Preface section.
- Install the screws to the recirculation actuator.
Tighten
Tighten the screws to 1.9 N·m (17 lb in).
- Install the air inlet assembly.
- Install the air inlet assembly screws.
Tighten
Tighten the screws to 1.9 N·m (17 lb in).
- Connect the electrical connector to the recirculation actuator.
- Install the HVAC module assembly. Refer to
HVAC Module Assembly Replacement.
- Recalibrate the recirculation actuator. Refer to
Actuator Recalibration