• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
ECT Sensor Signal | P0117 | P0118 | P0118* | P0116, P0128 |
Low Reference | -- | P0118 | P0118* | P0128 |
*ECM or sensor damage may occur if the circuit is shorted to B+ |
Circuit | Short to Ground | Open | Short to Voltage |
---|---|---|---|
Operating Conditions: Engine Operating in Closed Loop Parameter Normal Range: Varies with coolant temperature | |||
ECT Sensor Signal | 150°C (302°F) | -40°C (-40°F) | -40°C (-40°F) |
Low Reference | -- | -40°C (-40°F) | -40°C (-40°F) |
The engine coolant temperature (ECT) sensor is a variable resistor that measures the temperature of the engine coolant. The engine control module (ECM) supplies 5 volts to the ECT sensor signal circuit, and supplies a ground to the low reference circuit. The ECM uses this high side coolant rationality diagnostic to determine if the input from the ECT sensor is skewed warmer than normal. The internal clock of the ECM will record the amount of time the ignition is OFF. If the calibrated ignition OFF timer is met at start-up, the ECM will compare the temperature difference between the ECT and the intake air temperature (IAT) sensor to determine if the temperatures are within an acceptable operating range of each other.
• | DTCs P0112, P0113, P0117, P0118, P0601, P0602, P0603, P0604, P0606, P0607, P062F, P2610 are not set. |
• | The ignition is ON. |
• | The IAT parameter is greater than 15°C (59°F). |
• | The Fuel Level Sensor parameter is greater than 10 percent. |
• | The vehicle has a minimum ignition OFF time of 8 hours. |
• | The DTC runs once per ignition cycle when the above conditions are met. |
• | The ECM detects a temperature difference between the ECT sensor and the IAT sensor of greater than 100°C (180°F) at start-up. |
OR |
• | The ECM detects a temperature difference between the ECT sensor and the IAT sensor that is greater than 15°C (27°F) and the time elapsed cranking the engine without starting is greater than 5 seconds. |
OR |
• | The ECM detects a temperature difference between the ECT sensor and the IAT sensor that is greater than 15°C (27°F). The vehicle must then be driven for 5 minutes over 40 km/h (25 mph). If the IAT sensor temperature decreases greater than 5°C (9°F), an engine block heater was detected and the test is aborted. If the IAT sensor temperature does not decrease, an engine block heater was not detected and DTC P0116 will set. |
DTC P0116 is a Type B DTC.
DTC P0116 is a Type B DTC.
• | Inspect the ECT sensor terminals for corrosion and for engine coolant leaking through the sensor. Engine coolant that is leaking through the sensor will create a high resistance short to ground. This condition results in less voltage on the ECT sensor signal circuit, which is interpreted by the ECM as a warmer ECT. |
• | An IAT sensor that is skewed colder at various ambient temperatures due to greater resistance than is normal will increase the range between these two sensors. Measure and record the resistance of the IAT sensor at various ambient temperatures, then compare those measurements to the Temperature vs Resistance table. Refer to Temperature Versus Resistance. |
• | A slight to moderate resistance in the IAT sensor signal circuit or low reference circuit will increase the range between these two sensors. This condition results in a greater voltage on the IAT sensor signal circuit, which is interpreted by the ECM as a colder IAT. |
Powertrain Diagnostic Trouble Code (DTC) Type Definitions
Control Module References for scan tool information
⇒ | If greater than the specified range, test the low reference circuit for an open/high resistance. If the circuit tests normal, replace the ECM. |
⇒ | If warmer than the specified range, test the signal circuit terminal B for a short to ground. If the circuit tests normal, replace the ECM. |
⇒ | If colder than the specified range, test the signal circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the ECM. |
Measure and record the resistance of the ECT sensor at various ambient temperatures, then compare those measurements to the Temperature Versus Resistance table.
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for ECM replacement, setup, and programming |