Important: DO NOT apply thread sealant to the sensor threads. The sensor threads are coated at the factory. Applying additional sealant affects the sensors ability to detect detonation.
Notice: Refer to Fastener Notice in the Preface section.
Tighten
Tighten the sensor to 25 N·m (18 lb ft).