GM Service Manual Online
For 1990-2009 cars only
Makes
🢒
Chevrolet
🢒
2009
🢒
Uplander
🢒
HVAC
🢒
HVAC - Manual
🢒 Air Inlet Valve Actuator Replacement
Removal Procedure
Remove the upper instrument panel (I/P) trim pad.
Locate the recirculation actuator (2).
Disconnect the recirculation actuator electrical connector (1).
Remove the recirculation actuator bolts/screws (1).
Remove the recirculation actuator (7).
Remove the recirculation actuator levers (3, 6), if necessary. Note positioning for re-installation.
Installation Procedure
Install the recirculation actuator levers (3, 6), if necessary.
Install the recirculation actuator (7).
Caution:
Refer to
Fastener Caution
in the Preface section.
Install the recirculation actuator bolts/screws (1) and tighten to
1.2 N·m (11 lb in)
.
Connect the recirculation actuator electrical connector (1).
Install the upper I/P trim pad.
Re-calibrate the actuators. Refer to
Actuator Recalibration
.