Table 1: | A/C Performance Table |
Table 2: | A/C Performance Table - with Rear A/C |
This test measures the operating efficiency of the A/C system under the following conditions:
• | The current ambient air temperature |
• | The current relative humidity |
• | The high side pressure of the A/C system |
• | The low side pressure of the A/C system |
• | The temperature of the air being discharged into the passenger compartment |
The numbers below refer to the step numbers on the diagnostic table.
This step determines if the A/C system has at least the minimum refrigerant charge required to operate the system without damage.
This step measures the performance of the A/C system.
This step is to allow for vehicle variations as well as high ambient temperatures.
Step | Action | Values | Yes | No | ||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Important:
| ||||||||||||||||||||||||||||
Are both the low side and high side pressures within the specified value? | Greater than 16°C (60°F) - 345 kPa (50 psi) Greater than 24°C (75°F) - 483 kPa (70 psi) Greater than 33°C (90°F) - 690 kPa (100 psi) | Go to Step 2 | Go to Leak Testing | |||||||||||||||||||||||||
Important: Record the relative humidity and the ambient air temperature at the time of the test.
Important: Press the RESET button, before using the print function of J 43600 .
Does all the data recorded fall within the specified ranges of the table below? | -- | Go to Step 8 | Go to Step 3 | |||||||||||||||||||||||||
If the pressures and temperature recorded do not fall within the specified ranges, perform the following procedure:
Does all the data recorded fall within the specified ranges of the table below? | -- | Go to Step 8 | Go to Step 4 | |||||||||||||||||||||||||
4 | Do the pressures fall within the specified ranges, but the panel outlet temperature does not? | -- | Go to Step 5 | |||||||||||||||||||||||||
5 | Is the low side pressure greater than the specified range, but the high side pressure is within or less than the specified range? | -- | Go to Step 6 | |||||||||||||||||||||||||
6 | Are the low and high side pressures both greater than the specified ranges? | -- | Go to Step 7 | |||||||||||||||||||||||||
7 | Is the high side pressure greater than the specified range, but the low side pressure is within or less than the specified range? | -- | Go to Step 8 | |||||||||||||||||||||||||
8 | Operate the system in order to verify the test results. Did you find the same results? | -- | System OK |
Ambient Air Temperature | Relative Humidity | Service Port Pressure | Maximum Left Center Discharge Air Temperature | |
---|---|---|---|---|
Low Side | High Side | |||
13-18°C (55-65°F) | 0-100% | 151-213 kPa (22-31 psi) | 792-1212 kPa (115-176 psi) | 12°C (52°F) |
19-24°C (66-75°F) | Below 40% | 151-220 kPa (22-32 psi) | 847-1267 kPa (123-184 psi) | 12°C (52°F) |
Above 40% | 151-275 kPa (22-40 psi) | 971-1398 kPa (141-203 psi) | 15°C (59°F) | |
25-29°C (76-85°F) | Below 35% | 151-261 kPa (22-38 psi) | 1102-1502 kPa (160-218 psi) | 14°C (57°F) |
35-50% | 179-282 kPa (26-41 psi) | 1171-1550 kPa (170-225 psi) | 17°C (61°F) | |
Above 50% | 192-316 kPa (28-46 psi) | 1219-1557 kPa (177-226 psi) | 19°C (66°F) | |
30-35°C (86-95°F) | Below 30% | 192-310 kPa (28-45 psi) | 1302-1646 kPa (189-239 psi) | 18°C (64°F) |
30-50% | 213-337 kPa (31-49 psi) | 1336-1688 kPa (194-245 psi) | 20°C (68°F) | |
Above 50% | 241-372 kPa (35-54 psi) | 1398-1750 kPa (203-254 psi) | 23°C (73°F) | |
36-41°C (96-105°F) | Below 20% | 248-351 kPa (36-51 psi) | 1522-1860 kPa (221-270 psi) | 23°C (72°F) |
20-40% | 254-378 kPa (37-55 psi) | 1543-1880 kPa (224-273 psi) | 23°C (73°F) | |
Above 40% | 282-399 kPa (41-58 psi) | 1591-1908 kPa (231-277 psi) | 25°C (77°F) | |
42-46°C (106-115°F) | Below 20% | 303-399 kPa (44-58 psi) | 1756-2053 kPa (255-298 psi) | 25°C (77°F) |
Above 20% | 310-420 kPa (45-61 psi) | 1777-2060 kPa (258-299 psi) | 28°C (81°F) | |
47-49°C (116-120°F) | Below 30% | 358-454 kPa (52-66 psi) | 1970-2239 kPa (286-325 psi) | 30°C (86°F) |
Ambient Air Temperature | Relative Humidity | Service Port Pressure | Maximum Left Center A/C Discharge Air Temperature | Maximum Left/Top Rear A/C Discharge Air Temperature | |
---|---|---|---|---|---|
Low Side | High Side | ||||
13-18°C (55-65°F) | 0-100% | 151-289 kPa (22-42 psi) | 730-1212 kPa (106-176 psi) | 10°C (50°F) | 13°C (54°F) |
19-24°C (66-75°F) | Below 40% | 151-248 kPa (22-36 psi) | 709-1171 kPa (103-170 psi) | 10°C (50°F) | 13°C (55°F) |
Above 40% | 172-316 kPa (25-46 psi) | 757-1336 kPa (110-194 psi) | 13°C (55°F) | 17°C (61°F) | |
25-29°C (76-85°F) | Below 35% | 165-275 kPa (24-40 psi) | 978-1332 kPa (142-192 psi) | 13°C (54°F) | 15°C (59°F) |
35-60% | 199-296 kPa (29-43 psi) | 1067-1357 kPa (155-197 psi) | 13°C (55°F) | 17°C (61°F) | |
Above 60% | 227-337 kPa (33-49 psi) | 1129-1446 kPa (164-210 psi) | 15°C (59°F) | 18°C (64°F) | |
30-35°C (86-95°F) | Below 30% | 206-303 kPa (30-44 psi) | 1178-1653 kPa (171-240 psi) | 14°C (57°F) | 18°C (64°F) |
30-50% | 227-323 kPa (33-47 psi) | 1233-1688 kPa (179-245 psi) | 15°C (59°F) | 20°C (68°F) | |
Above 50% | 254-358 kPa (37-52 psi) | 1281-1722 kPa (186-250 psi) | 18°C (63°F) | 23°C (72°F) | |
36-41°C (96-105°F) | Below 20% | 227-337 kPa (33-49 psi) | 1419-1743 kPa (206-253 psi) | 17°C (61°F) | 20°C (68°F) |
20-40% | 254-351 kPa (37-51 psi) | 1205-1729 kPa (175-251 psi) | 18°C (63°F) | 23°C (72°F) | |
Above 40% | 275-378 kPa (40-55 psi) | 1446-1722 kPa (210-250 psi) | 18°C (64°F) | 24°C (75°F) | |
42-46°C (106-115°F) | Below 20% | 289-372 kPa (42-54 psi) | 1619-1929 kPa (235-280 psi) | 18°C (64°F) | 23°C (73°F) |
Above 20% | 296-378 kPa (43-55 psi) | 1619-1901 kPa (235-276 psi) | 19°C (66°F) | 25°C (77°F) | |
47-49°C (116-120°F) | Below 30% | 330-413 kPa (48-60 psi) | 1853-2239 kPa (269-325 psi) | 25°C (76°F) | 28°C (82°F) |