Auxiliary Blower Motor Replacement Without E59
Removal Procedure
- Remove the inflator air valve opening cover. Refer to
Inflator Air Valve Opening Cover Replacement
.
- Remove the screws from the hinged cover.
- Remove the cover from the rear trim panel.
- Release the tabs and pull out the trim panel.
- Disconnect the auxiliary blower motor electrical connector.
- Disconnect the auxiliary blower motor resistor electrical connector.
- Disconnect the auxiliary air temperature actuator electrical connector.
- Remove the auxiliary blower motor mounting screws.
- Remove the auxiliary blower motor from the blower motor housing.
Installation Procedure
- Install the auxiliary blower motor to the blower motor housing.
Notice: Refer to Fastener Notice in the Preface section.
- Install the auxiliary blower motor mounting screws.
Tighten
Tighten the screws to 1.6 N·m (14 lb in).
- Connect the auxiliary air temperature actuator electrical connector.
- Connect the auxiliary blower motor resistor electrical connector.
- Connect the auxiliary blower motor electrical connector.
- Install the trim panel and press firmly into the tabs.
- Align the cover and fasten the screws.
Tighten
Tighten the screws to 2.5 N·m (22 lb in).
- Install the inflator air valve opening cover. Refer to
Inflator Air Valve Opening Cover Replacement
.
Auxiliary Blower Motor Replacement With E59
Removal Procedure
- Remove the left lower quarter trim panel. Refer to
Inflator Air Valve Opening Cover Replacement
.
- Remove the power sliding door actuator and bracket.
Sliding Door Lock Actuator Replacement
.
- Disconnect the auxiliary blower motor electrical connector.
- Disconnect the auxiliary blower motor resistor electrical connector.
- Remove the lower auxiliary air distribution duct bolts and retainers.
- Remove the lower auxiliary air distribution duct.
Important: The auxiliary blower motor must be removed with the blower motor housing.
- Remove the auxiliary blower motor housing screws.
- Lift the auxiliary blower motor housing and remove from the HVAC module assembly.
- Remove the auxiliary blower motor mounting screws.
- Remove the auxiliary blower motor from the blower motor housing.
Installation Procedure
- Install the auxiliary blower motor to the blower motor housing.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the auxiliary blower motor mounting screws.
Tighten
Tighten the screws to 1.6 N·m (14 lb in).
- Install the blower motor housing to the auxiliary HVAC module assembly.
Align the rear tabs of the blower motor housing to the HVAC module.
- Install the auxiliary blower motor housing screws.
Tighten
Tighten the screws to 1.6 N·m (14 lb in).
- Install the lower auxiliary air distribution duct.
- Install the lower auxiliary air distribution retainers.
- Install the lower auxiliary air distribution ducts bolts.
Tighten
Tighten the bolts to 10 N·m (89 lb in).
- Connect the auxiliary blower motor resistor electrical connector.
- Connect the auxiliary blower motor electrical connector.
- Install the left lower quarter trim panel. Refer to
Rear Quarter Trim Panel Replacement - Right Side
.