• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
5-Volt Reference | 023 | 023 | 023 | -- |
Seat Belt Tension Sensor Signal | 023 | 023 | 023 | -- |
Low Reference | -- | 023 | -- | -- |
The inflatable restraint seat belt tension sensor is used to enhance the passenger presence system (PPS) when an infant car seat is properly restrained on the front outboard passenger seat. The seat belt tension sensor is a 3-wire potentiometer mounted on the lower seat belt anchor and provides an input to the PPS module. When an infant car seat is properly restrained on the front passenger seat, the seat belt is tightly secured through the infant car seat. The seat belt pulls on the tension sensor and changes the voltage signal to the PPS module. The PPS module uses the voltage signal to help determine if a tightly belted infant car seat is installed. The PPS uses the inputs from the seat belt tension sensor and the PPS pressure sensor to determine if the instrument panel (I/P) module should be suppressed or enabled.
Ignition 1 voltage is within the normal operating voltage range.
• | The PPS detects the voltage at the passenger seat belt tension sensor signal is less than 0.5 volt or greater than 4.5 volts for 500 milliseconds. |
• | The PPS detects the voltage at the passenger seat belt tension sensor 5-volt reference is less than 4.5 volts or greater than 9.1 volts for 500 milliseconds. |
• | The PPS detects the amperage at the passenger seat belt tension sensor low reference is 25 mA or greater for 500 milliseconds. |
• | The SDM disables the instrument panel (I/P) module deployment loop. |
• | The SDM requests the instrument panel cluster (IPC) to illuminate the AIR BAG indicator. |
• | The condition for setting the DTC no longer exists. |
• | A history DTC will clear once 255 malfunction-free ignition cycles have occurred. |
SIR System Description and Operation
Control Module References for scan tool information
⇒ | If less that the specified range, test the voltage reference circuit for open/high resistance or a short to ground. If the circuit tests normal, replace the PPS module. |
⇒ | If greater that the specified range, test the voltage reference circuit for a short to voltage. If the circuit tests normal, replace the PPS module. |
Important: The AIR BAG fuse that supplies ignition voltage must be removed to ensure the PPS module is inactive. An active PPS module may cause inaccurate resistance readings.
⇒ | If greater than the specified range, test the low reference circuit for open/high resistance. If the circuit tests normal, replace the PPS module. |
⇒ | If less than the specified value, test the signal circuit for a short to ground. |
⇒ | If greater than the specified range, test the signal circuit for a short to voltage. |
⇒ | If greater than the specified range, test the signal circuit for an open/high resistance. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for PPS replacement, setup, and programming |