GM Service Manual Online
For 1990-2009 cars only

Removal Procedure

  1. Remove the throttle body air inlet duct. Refer to Air Cleaner Inlet Duct Replacement .
  2. Use a flat-bladed tool in order to remove the automatic transaxle range selector cable from the cable lever and the bracket. Refer to Range Selector Lever Cable Replacement .

  3. Object Number: 161088  Size: SH
  4. Remove the automatic transaxle range selector cable bracket bolts.
  5. Remove the automatic transaxle range selector cable bracket.

Installation Procedure


    Object Number: 161088  Size: SH
  1. Install the automatic transaxle range selector cable bracket.
  2. Caution: Refer to Fastener Caution in the Preface section.

  3. Install the automatic transaxle range selector cable bracket bolts and tighten to 25 N·m (18 lb ft) .
  4. Install the automatic transaxle range selector cable to the cable lever and the bracket. Refer to Range Selector Lever Cable Replacement .
  5. Adjust the automatic transaxle range selector cable. Refer to Range Selector Lever Cable Adjustment .
  6. Install the throttle body air inlet duct. Refer to Air Cleaner Inlet Duct Replacement.