• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | High Resistance | Open | Short to Voltage | Signal Performance |
---|---|---|---|---|---|
Engine Oil Pressure 5-Volt Reference | P0522 | 1 | P0522 | P0523 | P0521 |
Engine Oil Pressure Sensor Signal | P0522 | 1 | P0522 | P0523 | P0521 |
Low Reference | -- | 1 | P0523 | -- | P0521 |
1. Engine Oil Pressure Indicator Malfunction |
The engine oil pressure (EOP) sensor changes voltage based on the engine oil pressure. The EOP sensor is a 3-wire sensor comprising of the signal circuit, the low reference circuit, and the 5-volt reference circuit. The engine control module (ECM) or the powertrain control module (PCM) supplies 5 volts to the EOP sensor via the 5-volt reference circuit and provides ground via the EOP low reference circuit. The ECM/PCM monitors the signal circuit of the EOP sensor to determine the engine oil pressure sensor voltage is within the normal operating range of approximately 1-4 volts. When the engine oil pressure is high, the EOP sensor voltage is high and the ECM/PCM senses a high signal voltage. When the engine oil pressure is low, the EOP sensor voltage is low and the ECM/PCM senses a low signal voltage. The ECM/PCM sends the EOP information to the instrument panel cluster (IPC) via the serial data circuit. The IPC illuminates the engine oil pressure indicator when it receives a serial data message indicating a low engine oil pressure condition.
Control Module References for scan tool information
⇒ | If greater than the specified range, test the low reference circuit for an open/high resistance. If the circuit tests normal, replace the ECM. |
⇒ | If less than the specified range, test the 5-volt reference circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the ECM. |
⇒ | If greater than the specified range, test the 5-volt reference circuit for a short to voltage. If the circuit tests normal, replace the ECM. |
⇒ | If greater than the specified range, test the signal circuit terminal C for a short to voltage. If the circuit tests normal, replace the ECM. |
⇒ | If less than the specified range, test the signal circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the ECM. |
⇒ | If the EOP indicator does not turn OFF, replace the IPC. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for the ECM and IPC replacement, setup, and programming. |